Automated determination of reboxetine by high-performance liquid chromatography with column-switching and ultraviolet detection

被引:40
作者
Härtter, S [1 ]
Weigmann, H [1 ]
Hiemke, C [1 ]
机构
[1] Univ Mainz, Dept Psychiat, D-55131 Mainz, Germany
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 740卷 / 01期
关键词
reboxetine;
D O I
10.1016/S0378-4347(00)00040-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fully automated method including column-switching and isocratic high-performance Liquid chromatography (HPLC) was developed for quantitative analysis of the new antidepressant reboxetine, a noradrenaline reuptake inhibitor. After serum injection into the HPLC system and on-line sample clean-up on a silica C-8 (10x4.0 mm I.D.) clean-up column with an eluent consisting of 2.5% acetonitrile in deionized water, the chromatographic separation was performed on an analytical column (Lichrospher CN; 250x4.6 mm I.D.) with an eluent of acetonitrile-aqueous potassium phosphate buffer (0.008 M, pH 6.4) (50:50). The UV detector was set at 273 or 226 nm. The limit of quantification was about 15 ng/ml at 273 nm and about 4 ng/ml at 226 nm. The day-to-day relative standard deviation ranged between 2.7 and 6.7% with recovery rates greater than or equal to 90%. Linear regression analyses revealed correlation coefficients >0.998. The method can be applied to therapeutic drug monitoring of reboxetine as well as pharmacokinetic studies. (C) 2000 Elsevier Science B. V. All rights reserved.
引用
收藏
页码:135 / 140
页数:6
相关论文
共 17 条
[1]  
Burrows GD, 1998, J CLIN PSYCHIAT, V59, P4
[2]   BINDING OF ANTIDEPRESSANTS TO HUMAN BRAIN RECEPTORS - FOCUS ON NEWER GENERATION COMPOUNDS [J].
CUSACK, B ;
NELSON, A ;
RICHELSON, E .
PSYCHOPHARMACOLOGY, 1994, 114 (04) :559-565
[3]   APPLICATIONS OF COLUMN-SWITCHING TECHNIQUE IN BIOPHARMACEUTICAL ANALYSIS .1. HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMITRIPTYLINE AND ITS METABOLITES IN HUMAN-PLASMA [J].
DADGAR, D ;
POWER, A .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 416 (01) :99-109
[4]   Pharmacology of antidepressants [J].
Frazer, A .
JOURNAL OF CLINICAL PSYCHOPHARMACOLOGY, 1997, 17 (02) :S2-S18
[5]   SENSITIVE PROCEDURE FOR THE DETERMINATION OF REBOXETINE ENANTIOMERS IN HUMAN PLASMA BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUOROMETRIC DETECTION AFTER CHIRAL DERIVATIZATION WITH (+)-1-(9-FLUORENYL)ETHYL CHLOROFORMATE [J].
FRIGERIO, E ;
PIANEZZOLA, E ;
BENEDETTI, MS .
JOURNAL OF CHROMATOGRAPHY A, 1994, 660 (1-2) :351-358
[6]  
HARTTER S, 1992, CLIN CHEM, V38, P2082
[7]   Serum concentrations of fluvoxamine and clinical effects - A prospective open clinical trial [J].
Hartter, S ;
Wetzel, H ;
Hammes, E ;
Torkzadeh, M ;
Hiemke, C .
PHARMACOPSYCHIATRY, 1998, 31 (05) :199-200
[8]  
Hiemke C, 1995, PSYCHOPHARMAKOTHERAP, V2, P21
[9]  
LEONARD B, 1994, J CLIN PSYCHIAT, V55, P459
[10]  
MATSUMOTO K, 1988, CLIN CHEM, V34, P141