Multiparametric ISODATA analysis of embolic stroke and rt-PA intervention in rat

被引:22
作者
Ding, GL
Quan, JA
Zhang, L
Zhang, ZG
Knight, RA
Soltanian Zadeh, H
Lu, M
Ewing, JR
Li, QJ
Whitton, PA
Chopp, M
机构
[1] Henry Ford Hlth Sci Ctr, Dept Neurol, Detroit, MI 48202 USA
[2] Henry Ford Hlth Sci Ctr, Dept Radiol, Detroit, MI 48202 USA
[3] Henry Ford Hlth Sci Ctr, Dept Biostat & Res Epidemiol, Detroit, MI 48202 USA
关键词
magnetic resonance imaging; focal embolic cerebral ischemia; unsupervised tissue segmentation technique; rt-PA intervention;
D O I
10.1016/j.jns.2004.05.017
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To increase the sensitivity of MRI parameters to detect tissue damage of ischemic stroke, an unsupervised analysis method, Iterative Self-Organizing Data Analysis Technique Algorithm (ISODATA), was applied to analyze the temporal evolution of ischemic damage in a focal embolic cerebral ischemia model in rat with and without recombinant tissue plasminogen activator (rt-PA) treatment. Male Wistar rats subjected to embolic stroke were investigated using a 7-T MRI system. Rats were randomized into control (n = 9) and treated (n 9) groups. The treated rats received rt-PA via a femoral vein at 4 h after onset of embolic ischemia. ISODATA analysis employed parametric maps or weighted images (T-1, T-2, and diffusion). ISODATA results with parametric maps are superior to ISODATA with weighted images, and both of them were highly correlated with the infarction size measured from the corresponding histological section. At 24 h after embolic stroke, the average map ISODATA lesion sizes were 37.7 +/- 7.0 and 39.2 +/- 5.6 mm(2) for the treated and the control group, respectively. Average histological infarction areas were 37.9 +/- 7.4 mm(2) for treated rats and 39.4 +/- 6.1 mm(2) for controls. The R-2 values of the linear correlation between map ISODATA and histological data were 0.98 and 0.96 for treated and control rats, respectively. Both histological and map ISODATA data suggest that there is no significant difference in infarction area between non-treated and rt-PA-treated rats when treatment was administered 4 h after the onset of embolic stroke. The ISODATA lesion size analysis was also sensitive to changes of lesion size during acute and subacute stages of stroke. Our data demonstrate that the multiparameter map ISODATA approach provides a more sensitive quantitation of the ischemic lesion at all time points than image ISODATA and single MRI parametric analysis using T-1, T-2 or ADC(w). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 53 条
[1]   Unsupervised, automated segmentation of the normal brain using a multispectral relaxometric magnetic resonance approach [J].
Alfano, B ;
Brunetti, A ;
Covelli, EM ;
Quarantelli, M ;
Panico, MR ;
Ciarmiello, A ;
Salvatore, M .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) :84-93
[2]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   FAST AND PRECISE T1 IMAGING USING A TOMROP SEQUENCE [J].
BRIX, G ;
SCHAD, LR ;
DEIMLING, M ;
LORENZ, WJ .
MAGNETIC RESONANCE IMAGING, 1990, 8 (04) :351-356
[5]   Intracerebral hemorrhage after intravenous t-PA therapy for ischemic stroke [J].
Brott, T ;
Broderick, J ;
Kothari, R ;
ODonoghue, M ;
Barsan, W ;
Tomsick, T ;
Spilker, J ;
Miller, R ;
Sauerbeck, L ;
Farrell, J ;
Kelly, J ;
Perkins, T ;
Miller, R ;
McDonald, T ;
Rorick, M ;
Hickey, C ;
Armitage, J ;
Perry, C ;
Thalinger, K ;
Rhude, R ;
Schill, J ;
Becker, PS ;
Heath, RS ;
Adams, D ;
Reed, R ;
Klei, M ;
Hughes, A ;
Anthony, J ;
Baudendistel, D ;
Zadicoff, C ;
Rymer, M ;
Bettinger, I ;
Laubinger, P ;
Schmerler, M ;
Meiros, G ;
Lyden, P ;
Dunford, J ;
Zivin, J ;
Rapp, K ;
Babcock, T ;
Daum, P ;
Persona, D ;
Brody, M ;
Jackson, C ;
Lewis, S ;
Liss, J ;
Mahdavi, Z ;
Rothrock, J ;
Tom, T ;
Zweifler, R .
STROKE, 1997, 28 (11) :2109-2118
[6]   Method for segmenting chest CT image data using an anatomical model: Preliminary results [J].
Brown, MS ;
McNitt-Gray, MF ;
Mankovich, NJ ;
Goldin, JG ;
Hiller, J ;
Wilson, LS ;
Aberle, DR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :828-839
[7]   DIFFUSION-WEIGHTED IMAGING STUDIES OF CEREBRAL-ISCHEMIA IN GERBILS - POTENTIAL RELEVANCE TO ENERGY FAILURE [J].
BUSZA, AL ;
ALLEN, KL ;
KING, MD ;
VANBRUGGEN, N ;
WILLIAMS, SR ;
GADIAN, DG .
STROKE, 1992, 23 (11) :1602-1612
[8]   MRI SEGMENTATION - METHODS AND APPLICATIONS [J].
CLARKE, LP ;
VELTHUIZEN, RP ;
CAMACHO, MA ;
HEINE, JJ ;
VAIDYANATHAN, M ;
HALL, LO ;
THATCHER, RW ;
SILBIGER, ML .
MAGNETIC RESONANCE IMAGING, 1995, 13 (03) :343-368
[9]   A COMPARISON OF ONE-SHOT AND RECOVERY METHODS IN T1-IMAGING [J].
CRAWLEY, AP ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :23-34
[10]   ANALYSIS OF DATA FROM MULTICLINIC TRIALS [J].
FLEISS, JL .