Accuracy of bedside chest hard-copy screen-film versus hard- and soft-copy computed radiographs in a medical intensive care unit: Receiver operating characteristic analysis

被引:22
作者
Kundel, HL
Gefter, W
Aronchick, J
Miller, W
Hatabu, H
Whitfill, CH
Miller, W
机构
[1] Department of Radiology, Pendergrass Diagn. Res. Laboratory, Univ. of Pennsylvania Medical School, Philadelphia, PA 19104-6086
关键词
radiography; bedside; comparative studies; computer-assisted;
D O I
10.1148/radiology.205.3.9393548
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare the clinical diagnostic accuracy of hard-copy readings of screen-film bedside chest radiographs and both hard-and soft-copy readings of bedside chest computed radiographs obtained in a medical intensive care unit. MATERIALS AND METHODS: Two samples of 95 cases were assembled from chest images obtained in 541 patients with either screen-film radiography or computed radiography. The cases were stratified according to the clinical problem for which the examination was ordered; the corresponding diagnosis was verified by a panel of two or three radiologists. Four radiologists blindly read the hard-copy images obtained with screen-film or computed radiography. Six months later, the radiologists read the computed radiographs by using an 8-bit, 1,684 x 2,048-pixel display. The data were analyzed by using multireader-multicase receiver operating characteristic (ROC) analysis of variance. RESULTS: No statistically significant differences in the area under the ROC curve were found between any of the methods. CONCLUSION: The results provide some justification for using bedside chest computed radiography and for reading soft-copy images from a high-quality display.
引用
收藏
页码:859 / 863
页数:5
相关论文
共 19 条
[1]   DETECTION OF BULLOUS LUNG-DISEASE - CONVENTIONAL RADIOGRAPHY VS DIGITAL STORAGE PHOSPHOR RADIOGRAPHY [J].
BUCKLEY, KM ;
SCHAEFER, CM ;
GREENE, R ;
AGATSTON, S ;
FAY, J ;
LLEWELLYN, HJ ;
MROSE, HE ;
RUBENS, JR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) :467-470
[2]   DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES [J].
CHAKRABORTY, DP ;
BREATNACH, ES ;
YESTER, MV ;
SOTO, B ;
BARNES, GT ;
FRASER, RG .
RADIOLOGY, 1986, 158 (01) :35-39
[3]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[4]   DETECTION OF PNEUMOTHORAX - COMPARISON OF DIGITAL AND CONVENTIONAL CHEST IMAGING [J].
FAJARDO, LL ;
HILLMAN, BJ ;
POND, GD ;
CARMODY, RF ;
JOHNSON, JE ;
FERRELL, WR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 152 (03) :475-480
[5]   OPERATING AT THE DIAGNOSTIC MARGINS - IMAGE QUALITY CONSIDERATIONS [J].
GUR, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (06) :1341-1342
[6]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843
[7]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[8]  
KEHLER M, 1991, ACTA RADIOL, V32, P18
[9]  
KEHLER M, 1990, ACTA RADIOL, V31, P47
[10]   THE APACHE-III PROGNOSTIC SYSTEM - RISK PREDICTION OF HOSPITAL MORTALITY FOR CRITICALLY ILL HOSPITALIZED ADULTS [J].
KNAUS, WA ;
WAGNER, DP ;
DRAPER, EA ;
ZIMMERMAN, JE ;
BERGNER, M ;
BASTOS, PG ;
SIRIO, CA ;
MURPHY, DJ ;
LOTRING, T ;
DAMIANO, A ;
HARRELL, FE .
CHEST, 1991, 100 (06) :1619-1636