A simple and reliable hemostatic technique during partial nephrectomy

被引:10
作者
Tsivian, A
Sidi, AA
机构
[1] E Wolfson Med Ctr, Dept Urol Surg, IL-58100 Holon, Israel
[2] Tel Aviv Univ, Sackler Fac Med, IL-69978 Tel Aviv, Israel
关键词
D O I
10.1016/j.urology.2004.01.028
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Introduction. To report our experience with a refined technique for hemostasis that obviates the need for vascular control and closure of the collecting system in partial nephrectomy. Technical Considerations. Four to five sutures, 2 cm apart, are placed 0.5 cm from the anticipated parenchymal incision border, using a specially designed, blunt-tip, straight needle with folded 2-0 Vicryl thread. The needle is removed, leaving the Vicryl thread with the loop on one side of the kidney and two free ends on the other side. A 1.0-cm-wide Vicryl mesh strip is passed circumferentially through the loops and between the free ends on each side, tension is applied on the strip during knotting of the free ends of the thread, and the tissue is incised. No additional hemostatic sutures are necessary. No attempt is made to identify and close the open collecting system. Vascular clamping and surface cooling are avoided. Sixty-one patients have undergone this technique since 1987: initially, for complicated nephrolithiasis (n = 15), localized purulent kidney disease (n = 4), trauma (n = 3), congenital anomalies (n = 2), and resection of horseshoe kidney (n = 6) and, recently, for peripherally located renal tumor (n = 3) Upper pole resection was performed in I I patients, lower pole resection in 45, and middle segment resection in 5. The blood loss was minimal, with only I patient developing gross hematuria that resolved after conservative treatment. No other complications occurred. Conclusions. A simple and easily performed hemostatic method suitable for peripherally located and, particularly, polar renal tumors is described. The Vicryl mesh strip prevents tears of the parenchymal sutures and ensures good hemostasis without closing the collecting system separately. (C) 2004 Elsevier Inc.
引用
收藏
页码:976 / 978
页数:3
相关论文
共 19 条
[1]
PARTIAL NEPHRECTOMY USING A LINEAR STAPLING DEVICE [J].
BANIEL, J ;
SCHEIN, M .
BRITISH JOURNAL OF UROLOGY, 1992, 69 (02) :218-218
[2]
Laparoscopic partial nephrectomy in the pig: Comparison of three hemostasis techniques [J].
Barret, E ;
Guillonneau, B ;
Cathelineau, X ;
Validire, P ;
Vallancien, G .
JOURNAL OF ENDOUROLOGY, 2001, 15 (03) :307-312
[3]
COMPLICATIONS OF NEPHRON SPARING SURGERY FOR RENAL TUMORS [J].
CAMPBELL, SC ;
NOVICK, AC ;
STREEM, SB ;
KLEIN, E ;
LICHT, M .
JOURNAL OF UROLOGY, 1994, 151 (05) :1177-1180
[4]
Laparoscopic partial nephrectomy with suture repair of the pelvicaliceal system [J].
Desai, MM ;
Gill, IS ;
Kaouk, JH ;
Matin, SF ;
Novick, AC .
UROLOGY, 2003, 61 (01) :99-104
[5]
PARTIAL NEPHRECTOMY USING A NEW DISSECTING INSTRUMENT [J].
GOLDWASSER, B ;
CARSON, CC ;
SHALABY, NF ;
OKE, EJ ;
WAIN, SL .
JOURNAL OF UROLOGY, 1986, 136 (01) :54-57
[6]
KIDNEY TOURNIQUET - A NEW INSTRUMENT FOR REGIONAL BLOOD CONTROL IN PARTIAL NEPHRECTOMY [J].
GOLDWASSER, BZ ;
CARSON, CC ;
SHALABY, NF ;
BERTRAM, RA .
UROLOGY, 1987, 30 (02) :162-163
[7]
CORONAL HEMOSTATIC SUTURE FOR PARTIAL NEPHRECTOMY [J].
HADDAD, FS ;
FLINT, PA .
BRITISH JOURNAL OF UROLOGY, 1991, 68 (03) :327-327
[8]
Posterior retroperitoneoscopic partial nephrectomy using microwave tissue coagulator for small renal tumors [J].
Itoh, K ;
Suzuki, Y ;
Miuru, M ;
Tsukigi, M ;
Ichiyanagi, O ;
Sasagawa, I .
JOURNAL OF ENDOUROLOGY, 2002, 16 (06) :367-371
[9]
Utility of the harmonic scalpel for laparoscopic partial nephrectomy [J].
Jackman, SV ;
Cadeddu, JA ;
Chen, RN ;
Micali, S ;
Bishoff, JT ;
Lee, BR ;
Moore, RG ;
Kavoussi, LR .
JOURNAL OF ENDOUROLOGY, 1998, 12 (05) :441-444
[10]
LEVINSON AK, 1991, UROLOGY, V38, P314