Value of multidetector computed tomography evaluation of myocardial perfusion in the assessment of ischemic heart disease: comparison with nuclear perfusion imaging

被引:24
作者
Kachenoura, Nadjia [1 ]
Lodato, Joseph A. [1 ]
Gaspar, Tamar [2 ]
Bardo, Dianna M. E. [1 ]
Newby, Barbara [1 ]
Gips, Sarah [2 ]
Peled, Nathan [2 ]
Lang, Roberto M. [1 ]
Mor-Avi, Victor [1 ]
机构
[1] Univ Chicago, Med Ctr, Chicago, IL 60637 USA
[2] Lady Davis Carmel Med Ctr, Haifa, Israel
关键词
Cardiovascular CT; Multidetector CT; Myocardial perfusion; CORONARY-ARTERY-DISEASE; LEFT-VENTRICULAR FUNCTION; MAGNETIC-RESONANCE; CT-ANGIOGRAPHY; NONINVASIVE DETECTION; DIAGNOSTIC-ACCURACY; CARDIAC-CT; INFARCTION; VIABILITY; QUANTIFICATION;
D O I
10.1007/s00330-009-1365-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
MDCT-derived myocardial perfusion has not yet been validated against accepted standards. We developed a technique for quantification of myocardial perfusion from MDCT images and studied its diagnostic value against SPECT myocardial perfusion imaging (MPI). Ninety-eight patients were studied. Abnormal perfusion was detected by comparing normalized segmental x-ray attenuation against values obtained in 20 control subjects. Disagreement with resting MPI was investigated in relationship to MDCT image quality, severity of MPI abnormalities, and stress MPI findings. Resting MPI detected mild or worse abnormalities in 20/78 patients. MDCT detected abnormalities in 15/20 patients (sensitivity of 0.75). Most abnormalities missed by MDCT analysis were graded as mild on MPI. Additional abnormalities found in 16/78 patients were not confirmed on resting MPI (specificity of 0.72). However, 8 of these 16 apparently false positive MDCT perfusion tests had abnormal stress MPI; of these 8 patients, 7 had optimal MDCT image quality, while in 6/8 remaining patients, image quality was suboptimal. When compared with resting MPI, MDCT detected perfusion abnormalities with high accuracy. Moreover, half of MDCT perfusion abnormalities not confirmed by resting MPI were associated with abnormal stress MPI. Importantly, this information can be obtained without additional radiation dose or contrast agent.
引用
收藏
页码:1897 / 1905
页数:9
相关论文
共 32 条
[1]
Assessment of the Myocardium on 2-Phase Cardiac Multidetector Computed Tomography: Does Cyclic Cardiac Contraction Influence Myocardial Attenuation? [J].
Boll, Daniel T. ;
Merkle, Elmar M. ;
Paulson, Erik K. ;
Hoffmann, Martin H. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2008, 32 (04) :602-608
[2]
Sixty-four-MSCT in the characterization of porcine acute and subacute myocardial infarction: Determination of transmurality in comparison to magnetic resonance imaging and histopathology [J].
Brodoefel, H. ;
Klumpp, B. ;
Reimann, A. ;
Fenchel, M. ;
Heuschmid, M. ;
Miller, S. ;
Schroeder, S. ;
Claussen, C. ;
Scheule, A. M. ;
Kopp, A. F. .
EUROPEAN JOURNAL OF RADIOLOGY, 2007, 62 (02) :235-246
[3]
Cardiac CT angiography (CTA) and nuclear myocardial perfusion imaging (MPI) - A comparison in detecting significant coronary artery disease [J].
Budoff, Matthew J. ;
Rasouli, M. Leila ;
Shavelle, David M. ;
Gopal, Ambarish ;
Gul, Khawar M. ;
Mao, Song S. ;
Liu, Steven H. ;
McKay, Charles R. .
ACADEMIC RADIOLOGY, 2007, 14 (03) :252-257
[4]
Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[5]
Comparison of MDCT and MRI in the detection and sizing of acute and chronic myocardial infarcts [J].
Choe, Yeon Hyeon ;
Choo, Ki Seok ;
Jeon, Eun-Seok ;
Gwon, Hyeon-Cheol ;
Choi, Jin-Ho ;
Park, Jeong-Euy .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 66 (02) :292-299
[6]
Comprehensive cardiac CT study: Evaluation of coronary arteries, left ventricular function, and myocardial perfusion - Is it possible? [J].
Cury, Ricardo C. ;
Nieman, Koen ;
Shapiro, Michael D. ;
Nasir, Khurram ;
Cury, Roberto C. ;
Brady, Thomas J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (02) :229-243
[7]
Applications of multislice computed tomography in coronary artery disease [J].
de Roos, Albert ;
Kroft, Lucia J. M. ;
Bax, Jeroen J. ;
Geleijns, Jacob .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) :14-22
[8]
Diagnostic value of the 16-detector row multislice spiral computed tomography for the detection of coronary artery stenosis in comparison to invasive coronary angiography [J].
Deetjen, Anja G. ;
Conradi, Guido ;
Moellmann, Susanne ;
Ekinci, Okan ;
Weber, Michael ;
Nef, Holger ;
Moellmann, Helge ;
Hamm, Christian W. ;
Dill, Thorsten .
CLINICAL CARDIOLOGY, 2007, 30 (03) :118-123
[9]
Quantification of myocardial perfusion using dynamic 64-detector computed tomography [J].
George, Richard T. ;
Jerosch-Herold, Michael ;
Silva, Caterina ;
Kitagawa, Kakuya ;
Bluenike, David A. ;
Linia, Joao A. C. ;
Lardo, Albert C. .
INVESTIGATIVE RADIOLOGY, 2007, 42 (12) :815-822
[10]
Multidetector computed tomography myocardial perfusion imaging during adenosine stress [J].
George, Richard T. ;
Silva, Caterina ;
Cordeiro, Marco A. S. ;
DiPaula, Anthony ;
Thompson, Douglas R. ;
McCarthy, William F. ;
Ichihara, Takashi ;
Lima, Joao A. C. ;
Lardo, Albert C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 48 (01) :153-160