Solid-phase extraction and preconcentration of cadmium(H) in aqueous solution with Cd(II)-imprinted resin (poly-Cd(II)-DAAB-VP) packed columns

被引:168
作者
Liu, YW [1 ]
Chang, XJ
Wang, S
Guo, Y
Din, BJ
Meng, SM
机构
[1] Lanzhou Univ, Sch Chem & Chem Engn, Lanzhou 730000, Peoples R China
[2] Shanxi Datong Univ, Dept Chem, Datong 037009, Shaanxi, Peoples R China
[3] Xi An Jiao Tong Univ, Sch Mat Sci & Engn, Xian 710049, Peoples R China
关键词
solid-phase extraction (SPE); metal ion imprinted polymer (MIIP); preconcentration; poly-Cd(II)-DAAB-VP; Cd(II); flame atomic absorption spectrometry (FAAS); natural water;
D O I
10.1016/j.aca.2004.06.017
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A novel chelating resin (poly-Cd(II)-DAAB-VP) was prepared by metal ion imprinted polymer (MIIP) technique. The resin was obtained by one pot reaction of Cd(II)-diazoaminobenzene-vinylpyridine with cross-linker ethyleneglycoldimethacrylate (EGDMA). Comparing with non-imprinted resin, the poly-Cd(II)-DAAB-VP has higher adsorption capacity and selectivity for Cd(II). The distribution ratio (D) values for the Cd(II)-imprinted resin show increase for Cd(II) with respect to both D values of Zn(II), Cu(II), Hg(II) and non-imprinted resin. The relatively selective factor (alpha(r)) values of Cd(II)/Cu(II), Cd(II)/Zn(II) and Cd(II)/Hg(II), are 51.2, 45.6, and 85.4, which are greater than 1. poly-Cd(II)-DAAB-VP can be used at least 20 times without considerable loss of adsorption capacity. Based on poly-Cd(II)-DAAB-VP packed columns. a highly selective solid-phase extraction (SPE) and preconcentration method for Cd(H) from aqueous solution was developed. The MIIP-SPE preconcentration procedure showed a linear calibration curve within concentration range from 0.093 to 30 mug1(-1). The detection limit and quantification limit were 0.093 and 0.21 mug1(-1) (3sigma) for flame atomic absorption spectrometry (FAAS). The relative standard deviation of the eleven replicate determinations was 3.7% for the determination of 10 mug of Cd(II) in 100 ml water sample. Determination of Cd(II) in certified river sediment sample (GBW 08301) demonstrated that the interfering matrix had been almost ramoved during preconcentration. The column was (Yood enough for Cd(II) determination in matrixes containing components with similar chemical property such as Cu(II), Zn(II) and Hg(III). (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:173 / 179
页数:7
相关论文
共 48 条
[1]
AKIMORO K, 2001, CHEM COMMUN, P1282
[2]
[Anonymous], 1998, HDB TOXICITY INORGAN
[3]
Lanthanide-imprinted resins prepared by surface template polymerization [J].
Araki, K ;
Yoshida, M ;
Uezu, K ;
Goto, M ;
Furusaki, S .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2000, 33 (04) :665-668
[4]
Determination of trace metals in seawater by inductively coupled plasma mass spectrometry after off-line dithiocarbamate solvent extraction [J].
Batterham, GJ ;
Munksgaard, NC ;
Parry, DL .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (11) :1277-1280
[5]
Ion imprinted polymer particles: synthesis, characterization and dysprosium ion uptake properties suitable for analytical applications [J].
Biju, VM ;
Gladis, JM ;
Rao, TP .
ANALYTICA CHIMICA ACTA, 2003, 478 (01) :43-51
[6]
ANALYTICAL FRACTIONATION OF LABILE METALS IN SELECTED GROUNDWATER HUMIC SUBSTANCES BY MEANS OF CHELATING ION-EXCHANGER [J].
BURBA, P ;
WILLMER, PG .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 342 (1-2) :167-171
[7]
Use of an o-aminobenzoic acid-functionalized XAD-4 copolymer resin for the separation and preconcentration of heavy metal(II) ions [J].
Çekiç, SD ;
Filik, H ;
Apak, R .
ANALYTICA CHIMICA ACTA, 2004, 505 (01) :15-24
[8]
Efficiency and application of poly(acryldinitrophenylamidrazone-dinitroacrylphenylhydrazine) chelating fiber for pre-concentrating and separating trace Au(III), Ru(III), In(III), Bi(III), Zr(IV), V(V), Ga(III) and Ti(IV) from solution samples [J].
Chang, XJ ;
Su, QQ ;
Liang, DY ;
Wei, XJ ;
Wang, BT .
TALANTA, 2002, 57 (02) :253-261
[9]
Efficiency and mechanism of new poly (acryl-phenylamidrazone phenylhydrazide) chelating fiber for adsorbing trace Ga, In, Bi, V and Ti from solution [J].
Chang, XJ ;
Yang, XL ;
Wei, XJ ;
Wu, KB .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :231-238
[10]
Metal-ion-templated polymers: Synthesis and structure of N-(4-vinylbenzyl)-1,4,7-triazacyclononanezinc(II) complexes, their copolymerization with divinylbenzene, and metal-ion selectivity studies of the demetalated resins - Evidence for a sandwich complex in the polymer matrix [J].
Chen, H ;
Olmstead, MM ;
Albright, RL ;
Devenyi, J ;
Fish, RH .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION IN ENGLISH, 1997, 36 (06) :642-645