A high resolution three dimensional T-1-weighted gradient echo sequence improves the detection of disease activity in multiple sclerosis

被引:41
作者
Filippi, M
Yousry, T
Horsfield, MA
Alkadhi, H
Rovaris, M
Campi, A
Voltz, R
Comi, G
机构
[1] UNIV MILAN,INST SCI,DEPT NEURORADIOL,OSPED SAN RAFFAELE,I-20132 MILAN,ITALY
[2] UNIV MUNICH,KLINIKUM GROSSHADERN,DEPT RADIOL,D-8000 MUNICH,GERMANY
[3] UNIV MUNICH,KLINIKUM GROSSHADERN,DEPT NEUROL,D-8000 MUNICH,GERMANY
[4] UNIV LEICESTER,DIV MED PHYS,LEICESTER,LEICS,ENGLAND
关键词
D O I
10.1002/ana.410400612
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
In this study, we performed a post-contrast magnetization-prepared rapid acquisition gradient echo (MP RAGE) sequence with subsequent reconstruction of axial slices with 5-, 3-, and I-mm thickness in 26 patients with multiple sclerosis (MS) to investigate the disease activity going on below the resolution of conventional scans. One hundred three enhancing lesions were detected using MP RAGE reconstructed with I-mm-thick slices, 93 using MP RAGE reconstructed with 3-mm-thick slices and 82 using MP RAGE reconstructed with 5-mm-thick slices. The detection rate using I-mm MP RAGE was 25.6% higher compared with 5-mm MP RAGE and 12% higher compared with 3-mm MP RAGE. Using l-mm MP RAGE, we detected five enhancing lesions in 2 of the 12 patients (16.6%) who showed no enhancing lesions on the 5-mm MP RAGE and one enhancing lesion in 1 of the 10 patients (10%) who showed no enhancing lesions on the 3-mm MP RAGE. The increased sensitivity of I-mm MP RAGE over the other two reconstruction slice thicknesses was due to improved detection of small lesions, located mainly in cortical/subcortical areas. These data indicate that the size of enhancing lesions in MS is highly variable, and that a significant proportion of disease activity goes undetected when performing conventional scans.
引用
收藏
页码:901 / 907
页数:7
相关论文
共 43 条
  • [1] MAGNETIC-RESONANCE RELAXATION-TIME MAPPING IN MULTIPLE-SCLEROSIS - NORMAL APPEARING WHITE-MATTER AND THE INVISIBLE LESION LOAD
    BARBOSA, S
    BLUMHARDT, LD
    ROBERTS, N
    LOCK, T
    EDWARDS, RHT
    [J]. MAGNETIC RESONANCE IMAGING, 1994, 12 (01) : 33 - 42
  • [2] BERRY I, 1996, P INT SOC MAGN RESON, V1, P536
  • [3] MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN
    BRANTZAWADZKI, M
    GILLAN, GD
    NITZ, WR
    [J]. RADIOLOGY, 1992, 182 (03) : 769 - 775
  • [4] BROWNELL B, 1962, ACTA NEUROL SCAND, V41, P1
  • [5] DAVIES SEC, 1995, J NEUROCHEM, V64, P742
  • [6] Quantitative assessment of MRI lesion load in monitoring the evolution of multiple sclerosis
    Filippi, M
    Horsfield, MA
    Tofts, PS
    Barkhof, F
    Thompson, AJ
    Miller, DH
    [J]. BRAIN, 1995, 118 : 1601 - 1612
  • [7] COMPARISON OF TRIPLE DOSE VERSUS STANDARD-DOSE GADOLINIUM-DTPA FOR DETECTION OF MRI ENHANCING LESIONS IN PATIENTS WITH PRIMARY PROGRESSIVE MULTIPLE-SCLEROSIS
    FILIPPI, M
    CAMPI, A
    MARTINELLI, V
    COLOMBO, B
    YOUSRY, T
    CANAL, N
    SCOTTI, G
    COMI, G
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1995, 59 (05) : 540 - 544
  • [8] Comparison of triple dose versus standard dose gadolinium-DTPA for detection of MRI enhancing lesions in patients with MS
    Filippi, M
    Yousry, T
    Campi, A
    Kandziora, C
    Colombo, B
    Voltz, R
    Martinelli, V
    Spuler, S
    Bressi, S
    Scotti, G
    Comi, G
    [J]. NEUROLOGY, 1996, 46 (02) : 379 - 384
  • [9] RESOLUTION-DEPENDENT ESTIMATES OF LESION VOLUMES IN MAGNETIC-RESONANCE-IMAGING STUDIES OF THE BRAIN IN MULTIPLE-SCLEROSIS
    FILIPPI, M
    HORSFIELD, MA
    CAMPI, A
    MAMMI, S
    PEREIRA, C
    COMI, G
    [J]. ANNALS OF NEUROLOGY, 1995, 38 (05) : 749 - 754
  • [10] A MAGNETIZATION-TRANSFER IMAGING STUDY OF NORMAL-APPEARING WHITE-MATTER IN MULTIPLE-SCLEROSIS
    FILIPPI, M
    CAMPI, A
    DOUSSET, V
    BARATTI, C
    MARTINELLI, V
    CANAL, N
    SCOTTI, G
    COMI, G
    [J]. NEUROLOGY, 1995, 45 (03) : 478 - 482