Shaping and cleaning the root canal system: A scanning electron microscopic evaluation of a new instrumentation and irrigation technique

被引:31
作者
Gambarini, G [1 ]
机构
[1] Univ Siena, Rome, Italy
关键词
D O I
10.1016/S0099-2399(99)80300-8
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of the present scanning electron microscopic study was to investigate the efficacy of a combination of EDTA, NaOCl, and surface-active irrigating solutions during and after root canal preparation with Profile nickel-titanium rotary instruments. Thirty canals were divided into three groups, instrumented and irrigated as follows: 5% NaOCl and a final flush with 17% EDTA were used for group A; group B specimens were irrigated using 17% EDTA, followed 15 s later by 1% TRITON X-100 (tensioactive agent) and then by 5% NaOCl; and group C specimens were irrigated with the same combination, but once shaping procedures were completed the irrigating sequence was repeated three times. After scanning electron microscopic evaluation, group C specimens exhibited the most effective debridement of the root canals. Results showed that tensioactive agent contributed to enhanced debridement. Cleaning was significantly improved once shaping procedures were completed.
引用
收藏
页码:800 / 803
页数:4
相关论文
共 16 条
[1]  
Abou-Rass M, 1981, J Endod, V7, P376, DOI 10.1016/S0099-2399(81)80059-3
[2]   THE PENETRATION OF SMEAR MATERIAL INTO DENTINAL TUBULES DURING INSTRUMENTATION WITH SURFACE-ACTIVE REAGENTS - A SCANNING ELECTRON-MICROSCOPIC STUDY [J].
AKTENER, BO ;
CENGIZ, T ;
PISKIN, B .
JOURNAL OF ENDODONTICS, 1989, 15 (12) :588-590
[3]  
ANDERSEN M, 1992, ENDOD DENT TRAUMATOL, V8, P104
[4]   Penetration ability of different irrigants into dentinal tubules [J].
Berutti, E ;
Marini, R ;
Angeretti, A .
JOURNAL OF ENDODONTICS, 1997, 23 (12) :725-727
[5]   THE EFFECT OF EDTA-CONTAINING SURFACE-ACTIVE SOLUTIONS ON THE MORPHOLOGY OF PREPARED DENTIN - AN INVIVO STUDY [J].
BRANNSTROM, M ;
NORDENVALL, KJ ;
GLANTZ, PO .
JOURNAL OF DENTAL RESEARCH, 1980, 59 (07) :1127-1131
[7]  
CAMERON JA, 1986, AUSTR DENT J, V31, P541
[8]   THE EFFECT OF DENTINAL TUBULE ORIENTATION ON THE REMOVAL OF SMEAR LAYER BY ROOT-CANAL IRRIGANTS - A SCANNING ELECTRON-MICROSCOPIC STUDY [J].
CENGIZ, T ;
AKTENER, BO ;
PISKIN, B .
INTERNATIONAL ENDODONTIC JOURNAL, 1990, 23 (03) :163-171
[9]   A COMPARISON OF ROOT-CANAL PREPARATIONS USING NI-TI HAND, NI-TI ENGINE-DRIVEN, AND K-FLEX ENDODONTIC INSTRUMENTS [J].
GLOSSON, CR ;
HALLER, RH ;
DOVE, SB ;
DELRIO, CE .
JOURNAL OF ENDODONTICS, 1995, 21 (03) :146-151
[10]   SCANNING ELECTRON-MICROSCOPE STUDY OF A NEW IRRIGATION METHOD IN ENDODONTIC TREATMENT [J].
GOLDMAN, LB ;
GOLDMAN, M ;
KRONMAN, JH ;
LIN, PS .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1979, 48 (01) :79-83