Ultrasonic enrichment of microspheres for ultrasensitive biomedical analysis in confocal laser-scanning fluorescence detection

被引:57
作者
Wiklund, M [1 ]
Toivonen, J
Tirri, M
Hänninen, P
Hertz, HM
机构
[1] AlbaNova, Royal Inst Technol, Biomed & Xray Phys, SE-10691 Stockholm, Sweden
[2] Univ Turku, Inst Biomed, Biophys Lab, FIN-20520 Turku, Finland
关键词
D O I
10.1063/1.1763226
中图分类号
O59 [应用物理学];
学科分类号
摘要
An ultrasonic particle concentrator based on a standing-wave hemispherical resonator is combined with confocal laser-scanning fluorescence detection. The goal is to perform ultrasensitive biomedical analysis by concentration of biologically active microspheres. The standing-wave resonator consists of a 4 MHz focusing ultrasonic transducer combined with the optically transparent plastic bottom of a disposable 96-well microplate platform. The ultrasonic particle concentrator collects suspended microspheres into dense, single-layer aggregates at well-defined positions in the sample vessel of the microplate, and the fluorescence from the aggregates is detected by the confocal laser-scanning system. The biochemical properties of the system are investigated using a microsphere-based human thyroid stimulating hormone assay. (C) 2004 American Institute of Physics.
引用
收藏
页码:1242 / 1248
页数:7
相关论文
共 31 条
[1]   A novel ultrasound-enhanced latex agglutination test for the detection of antibodies against Mycobacterium tuberculosis in serum [J].
Bhaskar, S ;
Banavaliker, JN ;
Bhardwaj, K ;
Upadhyay, P .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 262 (1-2) :181-186
[2]   Acoustic physics - Suspended by sound [J].
Brandt, EH .
NATURE, 2001, 413 (6855) :474-475
[3]  
Coakley WT, 1997, TRENDS BIOTECHNOL, V15, P506, DOI 10.1016/S0167-7799(97)01122-0
[4]   VORTICES AND STREAMS CAUSED BY SOUND WAVES [J].
ECKART, C .
PHYSICAL REVIEW, 1948, 73 (01) :68-76
[5]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[6]  
Gor'kov L. P., 1962, SOV PHYS DOKL, V6, P773, DOI DOI 10.1039/C004504G
[7]  
Groschl H, 1998, ACUSTICA, V84, P815
[8]  
Groschl M, 1998, ACUSTICA, V84, P432
[9]   Acoustically driven collection of suspended particles within porous media [J].
Gupta, S ;
Feke, DL .
ULTRASONICS, 1997, 35 (02) :131-139
[10]   A new microvolume technique for bioaffinity assays using two-photon excitation [J].
Hänninen, P ;
Soini, A ;
Meltola, N ;
Soini, J ;
Soukka, J ;
Soini, E .
NATURE BIOTECHNOLOGY, 2000, 18 (05) :548-550