PCDD/Fs and PCBs in airborne particulate matter of the greater Thessaloniki area, N. Greece

被引:57
作者
Kouimtzis, T
Samara, C
Voutsa, D [1 ]
Balafoutis, C
Müller, L
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Environm Pollut Control Lab, GR-54006 Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Dept Geol, Lab Meteorol & Climatol, GR-54006 Thessaloniki, Greece
[3] MPU GmbH, D-10829 Berlin, Germany
关键词
PCDDs; PCDFs; PCBs; particulate matter (TSP); partitioning; deposition; factor analysis;
D O I
10.1016/S0045-6535(01)00291-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/Fs and PCBs gave mean values of 0.52 and 0.59 pgI-TEQ/m(2)/day of PCDD/Fs, while 242 and 74 pg/m(2)/day of SigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:193 / 205
页数:13
相关论文
共 47 条
  • [1] PCDD/PCDF from emission sources and ambient air in northeast Spain
    Abad, E
    Caixach, J
    Rivera, J
    [J]. CHEMOSPHERE, 1997, 35 (03) : 453 - 463
  • [2] Improvements to the UK PCDD/F and PCB atmospheric emission inventory following an emissions measurement programme
    Alcock, RE
    Gemmill, R
    Jones, KC
    [J]. CHEMOSPHERE, 1999, 38 (04) : 759 - 770
  • [3] LONG-TERM HIGH-VOLUME AND LOW-VOLUME AIR SAMPLING OF POLYCHLORINATED DIBENZO-PARA-DIOXINS AND DIBENZOFURANS AND POLYCYCLIC AROMATIC-HYDROCARBONS ALONG A TRANSECT FROM URBAN TO REMOTE AREAS ON THE SWEDISH BALTIC COAST
    BROMAN, D
    NAF, C
    ZEBUHR, Y
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1991, 25 (11) : 1841 - 1850
  • [4] The effect of oils on PAH, PCDD, PCDF, and PCB emissions from a spark engine fueled with leaded gasoline
    Broz, J
    Grabic, R
    Kilián, J
    Lojkásek, M
    Marklund, S
    Ocelka, T
    Pekárek, V
    Pribyl, J
    Tydlitát, V
    Vyska, J
    [J]. CHEMOSPHERE, 2000, 41 (12) : 1905 - 1911
  • [5] Fingerprints of dioxin from thermal industrial processes
    Buekens, A
    Cornelis, E
    Huang, H
    Dewettinck, T
    [J]. CHEMOSPHERE, 2000, 40 (9-11) : 1021 - 1024
  • [6] A review of the processes involved in the exchange of semi-volatile organic compounds (SVOC) across the air-soil interface
    Cousins, IT
    Beck, AJ
    Jones, KC
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 228 (01) : 5 - 24
  • [7] Factors influencing atmospheric concentrations of polychlorinated biphenyls in Birmingham, UK
    Currado, GM
    Harrad, S
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (01) : 78 - 82
  • [8] Duarte-Davidson Raquel, 1994, Environmental Science and Pollution Research International, V1, P262, DOI 10.1007/BF02986542
  • [9] Dioxins in ambient air, bonfire night 1994
    Dyke, P
    Coleman, P
    James, R
    [J]. CHEMOSPHERE, 1997, 34 (5-7) : 1191 - 1201
  • [10] *EMEP, 1997, 898 EMEP CCC