Detrimental effects of BOLD signal in arterial spin Labeling fMRI at high field strength

被引:83
作者
Lu, Hanzhang
Donahue, Manus J.
van Zijl, Peter C. M.
机构
[1] Univ Texas, SW Med Ctr, Adv Imaging Res Ctr, Dallas, TX USA
[2] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21218 USA
[3] Kennedy Krieger Inst, FM Kirby Ctr, Baltimore, MD USA
关键词
arterial spin labeling; ASL; blood-oxygenation-level-dependent; BOLD; functional MRI; fMRI; cerebral blood flow; CBF; artifact; hemodynamic response;
D O I
10.1002/mrm.20976
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial spin labeling (ASL) MRI is a useful technique for noninvasive measurement of cerebral blood flow (CBF) in humans. High field strength provides a unique advantage for ASL because of longer blood T-1 relaxation times, making this technique a promising quantitative approach for functional brain mapping. However, higher magnetic field also introduces new challenges. Here it is shown that the CBF response determined using ASL functional MRI (fMRI) at 3.0 T contains significant contamination from blood-oxygenation-level-dependent (BOLD) effects. Due to interleaved acquisitions of label and control images, difference in blood oxygenation status between these two scans can cause incomplete cancellation of the static signal upon image subtraction, resulting in a BOLD-related artifact in the estimated CBF hemodynamics. If not accounted for, such an effect can complicate the interpretation of the ASL results, e.g., causing a delayed onset and offset of the response, or inducing an artifactual poststimulus undershoot. The BOLD contribution also decreases the sensitivity of ASL-based fMRI. Correction methods are proposed to reduce the artifact, giving increased number of activated voxels (18 +/- 5%, P = 0.006) and more accurate estimation of CBF temporal characteristics.
引用
收藏
页码:546 / 552
页数:7
相关论文
共 35 条
[1]   Experimental design and the relative sensitivity of BOLD and perfusion fMRI [J].
Aguirre, GK ;
Detre, JA ;
Zarahn, E ;
Alsop, DC .
NEUROIMAGE, 2002, 15 (03) :488-500
[2]   Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow [J].
Alsop, DC ;
Detre, JA .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1996, 16 (06) :1236-1249
[3]  
Alsop DC, 2000, ANN NEUROL, V47, P93, DOI 10.1002/1531-8249(200001)47:1<93::AID-ANA15>3.3.CO
[4]  
2-#
[5]   Temporal dynamics of the partial pressure of brain tissue oxygen during functional forepaw stimulation in rats [J].
Ances, BM ;
Buerk, DG ;
Greenberg, JH ;
Detre, JA .
NEUROSCIENCE LETTERS, 2001, 306 (1-2) :106-110
[6]   A general kinetic model for quantitative perfusion imaging with arterial spin labeling [J].
Buxton, RB ;
Frank, LR ;
Wong, EC ;
Siewert, B ;
Warach, S ;
Edelman, RR .
MAGNETIC RESONANCE IN MEDICINE, 1998, 40 (03) :383-396
[7]  
Calamante F, 1996, NMR BIOMED, V9, P79, DOI 10.1002/(SICI)1099-1492(199604)9:2<79::AID-NBM399>3.0.CO
[8]  
2-4
[9]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[10]  
DOBRE MC, 2005, P 13 ANN ISMRM MIAM, P1162