A novel self-assembled monolayer (SAM) coated microcantilever for low level caesium detection

被引:121
作者
Ji, HF
Finot, E
Dabestani, R
Thundat, T
Brown, GM
Britt, PF
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37831 USA
[2] Oak Ridge Natl Lab, Div Life Sci, Oak Ridge, TN 37831 USA
关键词
D O I
10.1039/a908143g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We report a new sensor concept based on an ion-selective SAM modified microcantilever which can detect caesium ion concentrations in situ in the range 10(-11)-10(-7) M and shows potential for use in developing a new family of real time in situ metal ion sensors with high sensitivity/selectivity and low cost, for chemical and biological applications.
引用
收藏
页码:457 / 458
页数:2
相关论文
共 15 条
  • [1] FORMATION OF MONOLAYER FILMS BY THE SPONTANEOUS ASSEMBLY OF ORGANIC THIOLS FROM SOLUTION ONTO GOLD
    BAIN, CD
    TROUGHTON, EB
    TAO, YT
    EVALL, J
    WHITESIDES, GM
    NUZZO, RG
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (01) : 321 - 335
  • [2] FAST CHROMATOGRAPHIC-SEPARATION TECHNIQUES AS COMPETITORS TO CHEMICAL AND BIOCHEMICAL SENSOR SYSTEMS
    CAMMANN, K
    KLEIBOHMER, W
    MUSSENBROCK, E
    ROSS, B
    ZUTHER, F
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 349 (05): : 338 - 345
  • [3] A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY
    CLEVELAND, JP
    MANNE, S
    BOCEK, D
    HANSMA, PK
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) : 403 - 405
  • [4] POLYMER MEMBRANES IN CLINICAL SENSOR APPLICATIONS .1. AN OVERVIEW OF MEMBRANE-FUNCTION
    DAVIES, ML
    HAMILTON, CJ
    MURPHY, SM
    TIGHE, BJ
    [J]. BIOMATERIALS, 1992, 13 (14) : 971 - 978
  • [5] Signaling recognition events with fluorescent sensors and switches
    de Silva, AP
    Gunaratne, HQN
    Gunnlaugsson, T
    Huxley, AJM
    McCoy, CP
    Rademacher, JT
    Rice, TE
    [J]. CHEMICAL REVIEWS, 1997, 97 (05) : 1515 - 1566
  • [6] Haverlock TJ, 1997, RADIOCHIM ACTA, V76, P103
  • [7] Novel cavity design using calix[n]arene skeletons: Toward molecular recognition and metal binding
    Ikeda, A
    Shinkai, S
    [J]. CHEMICAL REVIEWS, 1997, 97 (05) : 1713 - 1734
  • [8] THERMODYNAMIC AND KINETIC DATA FOR MACROCYCLE INTERACTION WITH CATIONS AND ANIONS
    IZATT, RM
    PAWLAK, K
    BRADSHAW, JS
    BRUENING, RL
    [J]. CHEMICAL REVIEWS, 1991, 91 (08) : 1721 - 2085
  • [9] Calix[4]arene-based Cs+ selective optical sensor
    Ji, HF
    Brown, GM
    Dabestani, R
    [J]. CHEMICAL COMMUNICATIONS, 1999, (07) : 609 - 610
  • [10] Lehn J. M, 1996, COMPREHENSIVE SUPRAM