Natural linewidth chemical shift imaging (NL-CSI)

被引:28
作者
Bashir, Adil [1 ]
Yablonskiy, Dmitriy A. [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
CSI; image reconstruction; magnetic field inhomogeneities; Gibbs ringing; NL-CSI;
D O I
10.1002/mrm.20917
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The discrete Fourier transform (FT) is a conventional method for spatial reconstruction of chemical shifting imaging (CSI) data. Due to point spread function (PSF) effects, FT reconstruction leads to intervoxel signal leakage (Gibbs ringing). Spectral localization by imaging (SLIM) reconstruction was previously proposed to overcome this intervoxel signal contamination. However, the existence of magnetic field inhomogeneities creates an additional source of intervoxel signal leakage. It is demonstrated herein that even small field inhomogeneities substantially amplify intervoxel signal leakage in both FT and SLIM reconstruction approaches. A new CSI data acquisition strategy and reconstruction algorithm (natural linewidth (NL) CSI) is presented that eliminates effects of magnetic field inhomogeneity-induced intervoxel signal leakage and intravoxel phase dispersion on acquired data. The approach is based on acquired CSI data, high-resolution images, and magnetic field maps. The data are reconstructed based on the imaged object structure (as in the SLIM approach) and a reconstruction matrix that takes into account the inhomogeneous field distribution inside anatomically homogeneous compartments. Phantom and in vivo results show that the new method allows field inhomogeneity effects from the acquired MR signal to be removed so that the signal decay is determined only by the "natural" R-2 relaxation rate constant (hence the term "natural linewidth" CSI).
引用
收藏
页码:7 / 18
页数:12
相关论文
共 37 条
[1]  
BOJORCK A, 1990, HDB NUMERICAL ANAL, V1, P589
[2]   SELECTIVE FOURIER-TRANSFORM LOCALIZATION [J].
BROOKER, HR ;
MARECI, TH ;
MAO, JT .
MAGNETIC RESONANCE IN MEDICINE, 1987, 5 (05) :417-433
[3]   NMR CHEMICAL-SHIFT IMAGING IN 3 DIMENSIONS [J].
BROWN, TR ;
KINCAID, BM ;
UGURBIL, K .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA-BIOLOGICAL SCIENCES, 1982, 79 (11) :3523-3526
[4]   Magnetic resonance spectroscopy as a measure of brain damage in multiple sclerosis [J].
De Stefano, N ;
Bartolozzi, ML ;
Guidi, L ;
Stromilloa, ML ;
Federico, A .
JOURNAL OF THE NEUROLOGICAL SCIENCES, 2005, 233 (1-2) :203-208
[5]   Improved spectral quality for 3D MR spectroscopic imaging using a high spatial resolution acquisition strategy [J].
Ebel, A ;
Maudsley, AA .
MAGNETIC RESONANCE IMAGING, 2003, 21 (02) :113-120
[6]   THE FOURIER-SERIES WINDOW METHOD FOR SPATIALLY LOCALIZED NMR-SPECTROSCOPY - IMPLEMENTATION WITH COMPOSITE PULSES AND MULTIPLE COILS [J].
GARWOOD, M ;
SCHLEICH, T ;
UGURBIL, K .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :512-515
[7]   The return of the frequency sweep: Designing adiabatic pulses for contemporary NMR [J].
Garwood, M ;
DelaBarre, L .
JOURNAL OF MAGNETIC RESONANCE, 2001, 153 (02) :155-177
[8]   IMPROVED FOURIER-SERIES WINDOWS FOR LOCALIZATION IN INVIVO NMR-SPECTROSCOPY [J].
GARWOOD, M ;
SCHLEICH, T ;
BENDALL, MR ;
PEGG, DT .
JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (03) :510-515
[9]  
Ghiglia D. C., 1998, 2 DIMENSIONAL PHASE
[10]   In vivo magnetic resonance spectroscopy in cancer [J].
Gillies, RJ ;
Morse, DL .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2005, 7 :287-326