Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice

被引:165
作者
Adler, A
Cieslewicz, G
Irvin, CG
机构
[1] Univ Ottawa, Sch Informat Technol & Engn, Ottawa, ON K1N 6N5, Canada
[2] Univ Vermont, Vermont Lung Ctr, Burlington, VT 05405 USA
[3] NIH, Dept Crit Care Med, Bethesda, MD 20892 USA
关键词
enhanced pause; airway resistance; lung mechanics;
D O I
10.1152/japplphysiol.00821.2003
中图分类号
Q4 [生理学];
学科分类号
071003 [生理学];
摘要
There has been significant utilization of the technique described by Hamelmann et al. (Am J Respir Crit Care Med 156: 766-775, 1997) in which a parameter, enhanced pause (Penh), related to airways responsiveness is noninvasively measured by unrestrained plethysmography (IT). Investigating this technique, we sought to answer these questions: 1) How do changes in Penh compare with changes in traditional plethysmographic and lung mechanical parameters? 2) How do UP parameters perform in two different mouse strains? Awake immunized and control BALB/c (n = 16) and C57BL/6 (n = 14) mice were placed in the UP chamber and exposed to doses of acrosolized methacholine while the following parameters were measured at each concentration: inspiratory time (TI), expiratory time (TE), total time (Ttot), Ti/Ttot, peak inspiratory pressure, peak expiratory pressure, Pause, Penh, tidal Volume (VT), VT/Ti, VT/TF, and VT/Ttot. The next day, lung resistance (RL) and compliance (CL) were invasively measured in the same animals. For the BALB/c, the parameters with the highest magnitude of correlation coefficient vs. RL are (in order) 1) CL, 2) Pause and Penh, 3) parameters of breathing frequency (TE, Ttot, TH, and 4) parameters related to VT (inspiratory pressure, expiratory pressure). Flow parameters (VT/Ttot, VT/TE, VT/TI) and duty cycle parameters (Tifrtot) had insignificant correlations. This ordering is significantly different in C57BL/6 mice, in which the parameters with the largest correlations are 1) CL, 2) parameters of breathing frequency, and 3) flow parameters. Pause, Penh, VT, and duty cycle parameters had insignificant correlations. These data show that Penh is problematic in the sense that it is strain specific; it behaves very differently in BALB/c and C57BL/6 mice. We suggest that UP parameters largely originate as part of reflex control of breathing processes, rather than in the lung mechanics and conclude that it is inappropriate to use UP parameters in general, and Penh specifically, as substitute variables for invasive mechanical indexes such as RL.
引用
收藏
页码:286 / 292
页数:7
相关论文
共 33 条
[1]
Temporal correlation of measurements of airway hyperresponsiveness in ovalbumin-sensitized mice [J].
Albertine, KH ;
Wang, L ;
Watanabe, S ;
Marathe, GK ;
Zimmerman, GA ;
McIntyre, TM .
AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2002, 283 (01) :L219-L233
[2]
BAI TR, 1987, AM REV RESPIR DIS, V135, P190
[3]
BERT P, 1868, CR SOC BIOL, V20, P22
[4]
BLEECKER ER, 1976, AM REV RESPIR DIS, V114, P909
[5]
VENTILATORY RESPONSE OF THE UNRESTRAINED AND UNANESTHETIZED HAMSTER TO CO2 [J].
CHAPIN, JL .
AMERICAN JOURNAL OF PHYSIOLOGY, 1954, 179 (01) :146-148
[6]
AIRWAY EPITHELIAL-CELL EXPRESSION OF INTERLEUKIN-6 IN TRANSGENIC MICE - UNCOUPLING OF AIRWAY INFLAMMATION AND BRONCHIAL HYPERREACTIVITY [J].
DICOSMO, BF ;
GEBA, GP ;
PICARELLA, D ;
ELIAS, JA ;
RANKIN, JA ;
STRIPP, BR ;
WHITSETT, JA ;
FLAVELL, RA .
JOURNAL OF CLINICAL INVESTIGATION, 1994, 94 (05) :2028-2035
[7]
DRORBAUGH JE, 1955, PEDIATRICS, V16, P81
[8]
Whole-body plethysmography, does it measure tidal volume of small animals? [J].
Enhorning, G ;
van Schaik, S ;
Lundgren, C ;
Vargas, I .
CANADIAN JOURNAL OF PHYSIOLOGY AND PHARMACOLOGY, 1998, 76 (10-11) :945-951
[9]
THEORETICAL-ANALYSIS OF BAROMETRIC METHOD FOR MEASUREMENT OF TIDAL VOLUME [J].
EPSTEIN, MAF ;
EPSTEIN, RA .
RESPIRATION PHYSIOLOGY, 1978, 32 (01) :105-120
[10]
PRACTICAL IMPLEMENTATION OF THE BAROMETRIC METHOD FOR MEASUREMENT OF TIDAL VOLUME [J].
EPSTEIN, RA ;
EPSTEIN, MAF ;
HADDAD, GG ;
MELLINS, RB .
JOURNAL OF APPLIED PHYSIOLOGY, 1980, 49 (06) :1107-1115