Spasticity-assessment: a review

被引:236
作者
Biering-Sorensen, F.
Nielsen, J. B.
Klinge, K.
机构
[1] Univ Copenhagen Hosp, Rigshosp, Ctr Neurosci, Clin Spinal Cord Injuries, DK-3100 Hornbaek, Denmark
[2] Univ Copenhagen, Panum Inst, Dept Med Physiol, DK-2200 Copenhagen N, Denmark
关键词
spasticity; assessment; measurement; clinical methods; biomechanical methods; electrophysiological methods;
D O I
10.1038/sj.sc.3101928
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study design: Review of the literature on the validity and reliability of assessment of spasticity and spasms. Objectives: Evaluate the most frequently used methods for assessment of spasticity and spasms, with particular focus on individuals with spinal cord lesions. Setting: Clinic for Spinal Cord Injuries, Rigshospitalet, University Hospital of Copenhagen, and Department of Medical Physiology, University of Copenhagen, Denmark. Methods: The assessment methods are grouped into clinical, biomechanical and electro-physiological, and the correlation between these is evaluated. Results: Clinical methods: For assessment of spasticity, the Ashworth and the modified Ashworth scales are commonly used. They provide a semiquantitative measure of the resistance to passive movement, but have limited interrater reliability. Guidelines for the testing procedures should be adhered to. Spasm frequency scales seem not to have been tested for reliability. Biomechanical methods such as isokinetic dynamometers are of value when an objective quantitative measure of the resistance to passive movement is necessary. They play a minor role in the daily clinical evaluation of spasticity. Electrophysiological methods: These techniques have provided valuable insight to the pathophysiological mechanisms involved in spasticity, but none of these techniques provide an easy and reliable assessment of spasticity for use in the daily clinic. Conclusion: A combination of electrophysiological and biomechanical techniques shows some promise for a full characterization of the spastic syndrome. There is a need of simple instruments, which provide a reliable quantitative measure with a low interrater variability.
引用
收藏
页码:708 / 722
页数:15
相关论文
共 90 条
[1]   Assessment of spasticity using isokinetic dynamometry in patients with spinal cord injury [J].
Akman, MN ;
Bengi, R ;
Karatas, M ;
Kilinç, S ;
Sözay, S ;
Özker, R .
SPINAL CORD, 1999, 37 (09) :638-643
[2]   Reliability of the Modified Ashworth Scale in the assessment of plantar flexor muscle spasticity in patients with traumatic brain injury [J].
Allison, SC ;
Abraham, LD ;
Petersen, CL .
INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 1996, 19 (01) :67-78
[3]   CORRELATION OF QUANTITATIVE MEASURES WITH THE MODIFIED ASHWORTH SCALE IN THE ASSESSMENT OF PLANTAR FLEXOR SPASTICITY IN PATIENTS WITH TRAUMATIC BRAIN INJURY [J].
ALLISON, SC ;
ABRAHAM, LD .
JOURNAL OF NEUROLOGY, 1995, 242 (10) :699-706
[4]  
ASHWORTH B, 1964, PRACTITIONER, V192, P540
[5]  
BAJD T, 1984, J BIOMED ENG, V6, P9, DOI 10.1016/0141-5425(84)90003-7
[6]   The relation between Ashworth scale scores and the excitability of the α motor neurones in patients with post-stroke muscle spasticity [J].
Bakheit, AMO ;
Maynard, VA ;
Curnow, J ;
Hudson, N ;
Kodapala, S .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2003, 74 (05) :646-648
[7]   Reliability of measurements obtained with the Modified Ashworth Scale in the lower extremities of people with stroke [J].
Blackburn, M ;
van Vliet, P ;
Mockett, SP .
PHYSICAL THERAPY, 2002, 82 (01) :25-34
[8]   INTERRATER RELIABILITY OF A MODIFIED ASHWORTH SCALE OF MUSCLE SPASTICITY [J].
BOHANNON, RW ;
SMITH, MB .
PHYSICAL THERAPY, 1987, 67 (02) :206-207
[9]   VARIABILITY AND RELIABILITY OF THE PENDULUM TEST FOR SPASTICITY USING A CYBEX-II ISOKINETIC DYNAMOMETER [J].
BOHANNON, RW .
PHYSICAL THERAPY, 1987, 67 (05) :659-661
[10]   USE OF A HAND-HELD DYNAMOMETER AND A KIN-COM(R) DYNAMOMETER FOR EVALUATING SPASTIC HYPERTONIA IN CHILDREN - A RELIABILITY STUDY [J].
BOITEAU, M ;
MALOUIN, F ;
RICHARDS, CL .
PHYSICAL THERAPY, 1995, 75 (09) :796-802