Centration and fixation of silicone intraocular lenses: Clinicopathological findings in human autopsy eyes

被引:16
作者
Auffarth, GU [1 ]
McCabe, C [1 ]
Wilcox, M [1 ]
Sims, JCR [1 ]
Wesendahl, TA [1 ]
Apple, DJ [1 ]
机构
[1] MED UNIV S CAROLINA,STORM EYE INST,DEPT OPHTHALMOL,CTR INTRAOCULAR LENS RES,CHARLESTON,SC 29425
关键词
D O I
10.1016/S0886-3350(96)80085-X
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze centration and fixation of three-piece and one-piece silicone intraocular lenses (IOLs) in human autopsy eyes. Setting: Center for Intraocular Lens Research, Medical University of South Carolina, Charleston. Methods: Thirty eyes among those submitted to the center between 1986 and 1994 were evaluated. The globes were sectioned at the equatorial plane and photographed from a posterior view. Gross examination was performed to determine IOL type, fixation, centration, and additional pathology. The results were compared with those of a control group of autopsy eyes implanted with one-piece and three-piece poly(methyl methacrylate) (PMMA) IOLs. The control group matched the silicone group in patient age, fixation site, and duration of implantation. Results: Twenty-three eyes (79.3%) had three-piece silicone IOLs and 7 eyes (20.7%), one-piece plate IOLs. Average patient age in the three-piece group was 77.3 years +/- 6.7 (SD) and in the one-piece group, 74.3 +/- 3.8 years. The 30 IOLs were symmetrically fixated in the bag. Average decentration of the three-piece and one-piece IOLs did not differ significantly, 0.37 +/- 0.31 mm and 0.26 +/- 0.13 mm, respectively (P = .37). There was also no significant difference in decentration between the silicone groups and the PMMA groups (P = .93). Conclusion: Centration and fixation of silicone IOLs were equivalent to those of standard PMMA IOLs.
引用
收藏
页码:1281 / 1285
页数:5
相关论文
共 26 条
[1]  
Apple D. J., 1989, INTRAOCULAR LENSES E
[2]   POSTERIOR CHAMBER INTRAOCULAR LENSES IN A SERIES OF 75 AUTOPSY EYES .1. LOOP LOCATION [J].
APPLE, DJ ;
PARK, SB ;
MERKLEY, KH ;
BREMS, RN ;
RICHARDS, SC ;
LANGLEY, KE ;
PIEST, KL ;
ISENBERG, RA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (04) :358-362
[3]   LONG-TERM RESULTS AFTER SILICON INTRAOCULAR-LENS IMPLANTATION [J].
ARTARIA, LG ;
ZILIOTTI, F ;
ZILIOTTIMANDELLI, A .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1994, 204 (05) :268-270
[4]  
ASSIA EI, 1993, OPHTHALMOLOGY, V100, P153
[5]  
Auffarth G. U., 1994, Ophthalmologe, V91, P507
[6]  
AUFFARTH GU, 1993, J LONG-TERM EFF MED, V3, P321
[7]   ANALYSIS OF 100 EXPLANTED ONE-PIECE AND 3-PIECE SILICONE INTRAOCULAR LENSES [J].
AUFFARTH, GU ;
WILCOX, M ;
SIMS, JCR ;
MCCABE, C ;
WESENDAHL, TA ;
APPLE, DJ .
OPHTHALMOLOGY, 1995, 102 (08) :1144-1150
[8]  
Auffarth GU, 1995, CATARACT SURG TECHNI, P314
[9]   EVALUATION OF THE BIOCOMPATIBILITY AND FIXATION OF A NEW SILICONE INTRAOCULAR-LENS IN THE FELINE MODEL [J].
BUCHEN, SY ;
RICHARDS, SC ;
SOLOMON, KD ;
APPLE, DJ ;
KNIGHT, PM ;
CHRIST, R ;
PHAM, LT ;
NELSON, DL ;
CLAYMAN, HM ;
KARPINSKI, LG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05) :545-553