Simultaneous flow injection determination of iron(II) and iron(III) with opto-electrochemical detection

被引:28
作者
Haghighi, B [1 ]
Safavi, A [1 ]
机构
[1] SHIRAZ UNIV,COLL SCI,DEPT CHEM,SHIRAZ 71454,IRAN
关键词
flow injection; optoelectrochemical detection; iron;
D O I
10.1016/S0003-2670(97)00436-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A two line manifold flow injection system with opto-electrochemical detection (simultaneous optical and electrochemical detection) is described for the simultaneous determination of Fe(II) and Fe(III). A modified Z-type flow cell is operated simultaneously as an optical flow cell for the spectrophotometric determination of Fe(III) by monitoring the absorbance of the sulfosalicylic acid-Fe(III) complex at 505 nm and as an electrochemical flow cell for amperometric monitoring of the current due to the oxidation of Fe(II) to Fe(III) at potential of +1.0 V vs. SCE. The optical and electrochemical signals are recorded simultaneously by two recorders. The calibration graphs are linear in the ranges 1x10(-6)-4x10(-4) M for Fe(III) and 1 x 10(-5) - 3 x 10(-3) M for Fe(II). The 3 sigma limits of detection of Fe(III) and Fe(II) are 4.3 x 10(-7) and 5.6 x 10(-6) M, respectively. The relative standard deviation of 16 determinations of 4 x 10(-5) M of Fe(III) and 1x10(-4) M of Fe(II) are 1.00% and 1.39%, respectively. Up to 75 samples per hour can be determined. The effects of several common ions on the determination of Fe(II) and Fe(III) are studied, showing that the method is relatively free from interferences. The method is applied to the simultaneous determination of Fe(II) and Fe(III) in spiked tap water. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 13 条
[1]   SPECIATION STUDIES BY FLOW-INJECTION ANALYSIS [J].
DECASTRO, MDL .
TALANTA, 1986, 33 (01) :45-50
[2]   DETERMINATION OF IRON(II) AND IRON(III) BY FLOW-INJECTION AND AMPEROMETRIC DETECTION WITH A GLASSY-CARBON ELECTRODE [J].
DIEKER, JW ;
VANDERLINDEN, WE .
ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) :267-274
[3]   APPLICATION OF A REDUCING COLUMN FOR METAL SPECIATION BY FLOW-INJECTION ANALYSIS - SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND SIMULTANEOUS DETERMINATION OF IRON(II) AND TOTAL IRON [J].
FAIZULLAH, AT ;
TOWNSHEND, A .
ANALYTICA CHIMICA ACTA, 1985, 167 (JAN) :225-231
[4]   ELECTROCHEMICAL APPROACHES TO TRACE-ELEMENT SPECIATION IN WATERS - A REVIEW [J].
FLORENCE, TM .
ANALYST, 1986, 111 (05) :489-505
[5]  
HAGHIGHI B, IN PRESS
[6]   SIMULTANEOUS DETERMINATION OF IRON(III) AND TOTAL IRON BY FLOW-INJECTION ANALYSIS USING KINETIC SPECTROPHOTOMETRY WITH TIRON [J].
KURODA, R ;
NARA, T ;
OGUMA, K .
ANALYST, 1988, 113 (10) :1557-1560
[7]   STUDIES ON THE APPLICATION OF PHOTOCHEMICAL-REACTIONS IN A FLOW-INJECTION SYSTEM .2. SIMULTANEOUS DETERMINATION OF IRON(II) AND IRON(III) BASED ON THE PHOTOREDUCTION OF THE IRON(III)-PHENANTHROLINE COMPLEX [J].
LIU, RM ;
LIU, DJ ;
SUN, AL .
ANALYST, 1992, 117 (11) :1767-1770
[8]   SPECIATION OF METALS IN SOLUTION BY FLOW-INJECTION ANALYSIS .2. DETERMINATION OF IRON(III) AND IRON(II) IN MINERAL PROCESS LIQUORS BY SIMULTANEOUS INJECTION INTO PARALLEL STREAMS [J].
LYNCH, TP ;
KERNOGHAN, NJ ;
WILSON, JN .
ANALYST, 1984, 109 (07) :843-846
[9]  
Miller J. C., 1984, STAT ANAL CHEM
[10]   DETERMINATION OF IRON IN NATURAL-WATERS AND PLANT-MATERIAL WITH 1,10-PHENANTHROLINE BY FLOW-INJECTION ANALYSIS [J].
MORTATTI, J ;
KRUG, FJ ;
PESSENDA, LCR ;
ZAGATTO, EAG ;
JORGENSEN, SS .
ANALYST, 1982, 107 (1275) :659-663