Selective solid-phase extraction of nickel(II) using a surface-imprinted silica gel sorbent

被引:149
作者
Jiang, Na
Chang, Xijun [1 ]
Zheng, Hong
He, Qun
Hu, Zheng
机构
[1] Lanzhou Univ, Sch Chem & Chem Engn, Lanzhou 730000, Peoples R China
[2] Qinghai Normal Univ, Xining 810008, Peoples R China
关键词
nickel(II)-imprinted amino-functionalized silica gel sorbent; preparation; solid-phase extraction (SPE); inductively coupled plasma atomic emission spectrometry (ICP-AES); surface imprinting technique;
D O I
10.1016/j.aca.2006.06.049
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new Ni(II)-imprinted amino-functionalized silica gel sorbent with excellent selectivity for nickel(II) was prepared by an easy one-step reaction by combining a surface imprinting technique for selective solid-phase extraction (SPE) of trace Ni(II) in water samples prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Compared with non-imprinted polymer particles, the ion-imprinted polymers (IIPs) had higher selectivity and adsorption capacity for Ni(II). The maximum static adsorption capacity of the ion-imprinted and non-imprinted sorbent for Ni(II) was 12.61 and 4.25 mg g(-1), respectively. The relatively selective factor (alpha(r)) values of Ni(II)/Cu(II), Ni(II)/Co(II), Ni(II)/Zn(II) and Ni(II)/Pd(II) were 45.99, 32.83, 43.79 and 28.36, which were greater than 1. The distribution ratio (D) values of Ni(II)-imprinted polymers for Ni(II) were greatly larger than that for Cu(II), Co(II), Zn(II) and Pd(II). The detection limit (3 sigma) was 0.16 ng mL(-1). The relative standard deviation of the method was 1.48% for eight replicate determinations. The method was validated by analyzing two certified reference materials (GBW 08618 and GBW 08402), the results obtained is in good agreement with standard values. The developed method was also successfully applied to the determination of trace nickel in plants and water samples with satisfactory results. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:225 / 231
页数:7
相关论文
共 34 条
[1]   Ion-selective imprinted beads for aluminum removal from aqueous solutions [J].
Andaç, M ;
Özyapi, E ;
Senel, S ;
Say, R ;
Denizli, A .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (05) :1780-1786
[2]   Molecularly imprinted ion exchange resin for purification, preconcentration and determination of UO22+ by spectrophotometry and plasma spectrometry [J].
Bae, SY ;
Southard, GL ;
Murray, GM .
ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) :173-181
[3]   SYNTHESIS AND PROPERTIES OF CHEMICALLY MODIFIED DIHYDROXY-FUNCTIONAL, HYDROXYAMINO-FUNCTIONAL AND AMINO-FUNCTIONAL SILICA PACKINGS IN ADSORPTION CHROMATOGRAPHY [J].
BECKER, N ;
UNGER, K .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 304 (05) :374-381
[4]   Hierarchically imprinted sorbents for the separation of metal ions [J].
Dai, S ;
Burleigh, MC ;
Ju, YH ;
Gao, HJ ;
Lin, JS ;
Pennycook, SJ ;
Barnes, CE ;
Xue, ZL .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (05) :992-993
[5]   Preconcentrative separation of palladium(II) using palladium(II) ion-imprinted polymer particles formed with different quinoline derivatives and evaluation of binding parameters based on adsorption isotherm models [J].
Daniel, S ;
Babu, PEJ ;
Rao, TP .
TALANTA, 2005, 65 (02) :441-452
[6]   Bioimprinting of polymers and sol-gel phases. Selective detection of yeasts with imprinted polymers [J].
Dickert, FL ;
Hayden, O .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1302-1306
[7]   Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packed-bed columns [J].
Ersöz, A ;
Say, R ;
Denizli, A .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :91-97
[8]   An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II) [J].
Fang, GZ ;
Tan, J ;
Yan, XP .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1734-1739
[9]   The effect of freshwater UV-irradiation prior to resin preconcentration of trace metals [J].
Guéguen, C ;
Belin, C ;
Thomas, BA ;
Monna, F ;
Favarger, PY ;
Dominik, J .
ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) :155-159
[10]   Preparation and evaluation of a molecularly imprinted sol-gel material for on-line solid-phase extraction coupled with high performance liquid chromatography for the determination of trace pentachlorophenol in water samples [J].
Han, DM ;
Fang, GZ ;
Yan, XP .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (02) :131-136