A compilation of new and published major and trace element data for NIST SRM 610 and NIST SRM 612 glass reference materials

被引:2421
作者
Pearce, NJG
Perkins, WT
Westgate, JA
Gorton, MP
Jackson, SE
Neal, CR
Chenery, SP
机构
[1] UNIV TORONTO,SCARBOROUGH COLL,DIV PHYS SCI,SCARBOROUGH,ON M1C 1A4,CANADA
[2] MEM UNIV NEWFOUNDLAND,DEPT EARTH SCI,ST JOHNS,NF A1B 3X5,CANADA
[3] UNIV NOTRE DAME,DEPT CIVIL ENGN & GEOL SCI,NOTRE DAME,IN 46556
[4] BRITISH GEOL SURVEY,KEYWORTH NG12 5GG,NOTTS,ENGLAND
来源
GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS | 1997年 / 21卷 / 01期
关键词
D O I
10.1111/j.1751-908X.1997.tb00538.x
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
Microanalytical trace element techniques (such as ion probe or laser ablation ICP-MS) are hampered by a lack of well characterized, homogeneous standards. Two silicate glass reference materials produced by National Institute of Standards and Technology (NIST), NIST SRM 610 and NIST SRM 612, have been shown to be homogeneous and are spiked with up to sixty one trace elements at nominal concentrations of 500 mu g g(-1) and 50 mu g g(-1) respectively. These samples (supplied as 3 mm wafers) are equivalent to NIST SRM 611 and NIST SRM 613 respectively (which are supplied as 1 mm wafers) and are becoming more widely used as potential microanalytical reference materials. NIST however, only certifies vp to eight elements in these glasses. Here we have compiled concentration data from approximately sixty published works for both glasses, and have produced new analyses from our laboratories. Compilations are presented for the matrix composition of these glasses and for fifty eight trace elements. The trace element data includes all available new and published data, and summaries present the overall average and standard deviation, the range, median, geometric mean and a preferred average (which excludes all data outside +/- one standard deviation of the overall average). For the elements which have been certified, there is a good agreement between the compiled averages and the NIST data. This compilation is designed to provide useful new working values for these reference materials.
引用
收藏
页码:115 / 144
页数:30
相关论文
共 83 条
[1]  
ABBEY S, 1979, GEOSTANDARD NEWSLETT, V2, P121
[2]   DETERMINATION OF LEAD, URANIUM, THORIUM, AND THALLIUM IN SILICATE GLASS STANDARD MATERIALS BY ISOTOPE DILUTION MASS-SPECTROMETRY [J].
BARNES, IL ;
GARNER, EL ;
GRAMLICH, JW ;
MOORE, LJ ;
MURPHY, TJ ;
MACHLAN, LA ;
SHIELDS, WR ;
TATSUMOT.M ;
KNIGHT, RJ .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :880-885
[3]   TRACE-ELEMENT ANALYSIS BY NEUTRON-ACTIVATION WITH A LOW FLUX REACTOR (SLOWPOKE-II) - RESULTS FOR INTERNATIONAL REFERENCE ROCKS [J].
BARNES, SJ ;
GORTON, MP .
GEOSTANDARDS NEWSLETTER, 1984, 8 (01) :17-23
[4]   HIGH-RESOLUTION SIMS ANALYSIS OF COMMON LEAD [J].
BELSHAW, NS ;
ONIONS, RK ;
MARTEL, DJ ;
BURTON, KW .
CHEMICAL GEOLOGY, 1994, 112 (1-2) :57-70
[5]   METAL EXTRACTION BY HYDROFLUORIC-ACID FROM SLURRIES OF GLASS MATERIALS IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (07) :695-710
[6]   THE INFLUENCE OF PYROLYSIS AND MATRIX MODIFIERS FOR ANALYSIS OF GLASS MATERIALS BY GFAAS USING SLURRY SAMPLE INTRODUCTION [J].
BENDICHO, C ;
DELOOSVOLLEBREGT, MTC .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1990, 45 (07) :679-693
[7]   GEOCHEMICAL UTILIZATION OF NUCLEAR MICROPROBES [J].
BENJAMIN, TM ;
DUFFY, CJ ;
ROGERS, PSZ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 30 (03) :454-458
[8]   SPARK-SOURCE MASS-SPECTROMETRIC ANALYSIS OF NBS-SRM 610 (3MM) STANDARD [J].
BERGHOLZ, J ;
LUCK, J ;
MOLLER, P ;
SZACKI, W .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1974, 269 (02) :121-121
[9]   MATERIALS ANALYSIS BY LASER-PROBE MASS-SPECTROMETRY [J].
BINGHAM, RA ;
SALTER, PL .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1976, 21 (1-2) :133-144
[10]  
BONHAM RW, 1989, SPECTROSCOPY INT, V1, P42