The use of a dual-articulation acetabular cup system to prevent dislocation after primary total hip arthroplasty: analysis of 384 cases at a mean follow-up of 15 years

被引:170
作者
Philippot, Remi [1 ]
Camilleri, Jean Philippe [1 ]
Boyer, Bertrand [1 ]
Adam, Philippe [1 ]
Farizon, Frederic [1 ]
机构
[1] Hop Bellevue, F-42000 St Etienne, France
关键词
FEMORAL-HEAD; REPLACEMENT; POLYETHYLENE; SOCKETS; FAILURE; RISK; COMPONENTS; MECHANISMS; MOBILITY; IMPLANTS;
D O I
10.1007/s00264-008-0589-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
The concept of a dual articulation acetabular cup was developed by Prof. Bousquet in 1974. This concept has been shown to provide high stability after revision and primary total hip arthroplasty. The aim of our study was to evaluate the incidence of prosthetic instability in a consecutive homogeneous series of 384 primary dual mobility cups. Incidence of instability and implant survival were evaluated. Mean follow-up was 15.3 years (range, 12-20). There was no early or late instability. On the acetabular side there were 13 aseptic loosenings, 14 intraprosthetic dislocations, and seven polyethylene wear cases that required replacement of the liner. The cumulative survival rate of the dual-articulation acetabular cup using surgical revision for aseptic loosening as the endpoint was 95.9% +/- 4.1% at 18 years postoperatively. Our series proves the good long term behaviour of dual-articulation acetabular components in primary arthroplasty. Their excellent survivorship rate and the absence of episodes of prosthetic instability increase our confidence in this concept.
引用
收藏
页码:927 / 932
页数:6
相关论文
共 25 条
[1]
Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants [J].
Adam, P ;
Farizon, F ;
Fessy, MH .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2005, 91 (07) :627-636
[2]
Anderson M J, 1994, J Arthroplasty, V9, P17, DOI 10.1016/0883-5403(94)90133-3
[3]
The cumulative long-term risk of dislocation after primary Charnley total hip arthroplasty [J].
Berry, DJ ;
Von Knoch, M ;
Schleck, CD ;
Harmsen, WS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (01) :9-14
[4]
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[5]
Femoral head sizes larger than 32 mm against highly cross-linked polyethylene [J].
Burroughs, BR ;
Rubash, HE ;
Harris, WH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :150-157
[6]
Use of a constrained tripolar acetabular liner to treat intraoperative instability and postoperative dislocation after total hip arthroplasty [J].
Callaghan, JJ ;
O'Rourke, MR ;
Goetz, DA ;
Lewallen, DG ;
Johnston, RC ;
Capello, WN .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :117-123
[7]
CHANDLER RW, 1982, CLIN ORTHOP RELAT R, P168
[8]
Early failure mechanisms of constrained tripolar acetabular sockets used in revision total hip arthroplasty [J].
Cooke, CC ;
Hozack, W ;
Lavernia, C ;
Sharkey, P ;
Shastri, S ;
Rothman, RH .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :827-833
[10]
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20