Volumetric retinal imaging with ultrahigh-resolution spectral-domain optical coherence tomography and adaptive optics using two broadband light sources

被引:74
作者
Cense, Barry [1 ]
Koperda, Eric [1 ]
Brown, Jeffrey M. [1 ]
Kocaoglu, Omer P. [1 ]
Gao, Weihua [1 ]
Jonnal, Ravi S. [1 ]
Miller, Donald T. [1 ]
机构
[1] Indiana Univ, Sch Optometry, Bloomington, IN 47405 USA
来源
OPTICS EXPRESS | 2009年 / 17卷 / 05期
基金
美国国家科学基金会;
关键词
HIGH-SPEED;
D O I
10.1364/OE.17.004095
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Ultrabroadband sources, such as multiplexed superluminescent diodes (SLDs) and femtosecond lasers, have been successfully employed in adaptive optics optical coherence tomography (AO-OCT) systems for ultrahigh resolution retinal imaging. The large cost differential of these sources, however, motivates the need for a performance comparison. Here, we compare the performance of a Femtolasers Integral Ti:Sapphire laser and a Superlum BroadLighter T840, using the same AO-OCT system and the same subject. In addition, we investigate the capability of our instrument equipped with the Integral to capture volume images of the fovea and adjacent regions on a second subject using the AO to control focus in the retina and custom and freeware image registration software to reduce eye motion artifacts. Monochromatic ocular aberrations were corrected with a woofer-tweeter AO system. Coherence lengths of the Integral and BroadLighter were measured in vivo at 3.2 mu m and 3.3 mu m, respectively. The difference in dynamic range was 5 dB, close to the expected variability of the experiment. Individual cone photoreceptors, retinal capillaries and nerve fiber bundles were distinguished in all three dimensions with both sources. The acquired retinal volumes are provided for viewing in OSA ISP, allowing the reader to data mine at the microscope level. (C) 2009 Optical Society of America
引用
收藏
页码:4095 / 4111
页数:17
相关论文
共 29 条
[1]  
Abramoff M. D., 2004, BIOPHOTONICS INT, V11, P36, DOI DOI 10.1201/9781420005615.AX4
[2]  
*ANSI, 2007, Z136 1 SAF US LAS
[3]   Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imaging [J].
Bedggood, Phillip ;
Daaboul, Mary ;
Ashman, Ross ;
Smith, George ;
Metha, Andrew .
JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (02)
[4]   Compact multimodal adaptive-optics spectral-domain optical coherence tomography instrument for retinal imaging [J].
Bigelow, Chad E. ;
Iftimia, Nicusor V. ;
Ferguson, R. Daniel ;
Ustun, Teoman E. ;
Bloom, Benjamin ;
Hammer, Daniel X. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1327-1336
[5]  
Bloom W.D. W. Fawcett., 1975, TXB HISTOLOGY, V3rd
[6]   Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography [J].
Cense, B ;
Nassif, NA ;
Chen, T ;
Pierce, M ;
Yun, SH ;
Park, BH ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS EXPRESS, 2004, 12 (11) :2435-2447
[7]   High-resolution adaptive optics scanning laser ophthalmoscope with dual deformable mirrors [J].
Chen, Diana C. ;
Jones, Steven M. ;
Silva, Dennis A. ;
Olivier, Scot S. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1305-1312
[8]   HUMAN PHOTORECEPTOR TOPOGRAPHY [J].
CURCIO, CA ;
SLOAN, KR ;
KALINA, RE ;
HENDRICKSON, AE .
JOURNAL OF COMPARATIVE NEUROLOGY, 1990, 292 (04) :497-523
[9]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[10]   Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices [J].
Delori, Francois C. ;
Webb, Robert H. ;
Sliney, David H. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1250-1265