Upgrading mixed ventilation systems in industrial conditioning

被引:21
作者
Caputo, Antonio C. [1 ]
Pelagagge, Pacifico M. [1 ]
机构
[1] Univ Laquila, Dept Mech Energy & Management Engn, Laquila, Italy
关键词
Mixing ventilation; Displacement ventilation; Economic analysis; Industrial ventilation; Retrofit; DISPLACEMENT VENTILATION;
D O I
10.1016/j.applthermaleng.2009.04.025
中图分类号
O414.1 [热力学];
学科分类号
摘要
Mixing ventilation systems (MVS) involve injecting cold air from the upper part of the room. The resulting turbulent mixing of the cold stream with ambient air determines a cooling of the whole volume and establishes an uniform temperature level with a very low vertical temperature gradient. While this method is commonly practiced it may not be energy efficient as the entire room volume gets cooled while often only the lower room volume, occupied by personnel at the shop floor level, needs conditioning. This may be a severe drawback especially in high-ceiling buildings and when process equipment with high thermal loads are utilized. In this paper an easily retrofitted improvement solution to existing MVS, called retrofit hybrid displacement ventilation system (RHDVS) is suggested and compared with a traditional MVS taking into account technical and economic performances. The study was carried out resorting to experimental measurements on a single-diffuser pilot installation of the RHDVS in an actual industrial facility, to characterize the existing MVS and estimate the performance improvement obtainable with the proposed RHDVS. An economic analysis was finally performed to assess the retrofit economic feasibility in case it is extended to the entire plant. Respect mixing ventilation, a reduction of the air flow rate cooling requirement from 12 to 6 kJ/kg resulted in the considered application, with an average cost saving of 50,000 (sic)/yr. A pay back time of less than 1 year followed, making the upgrade to RHDVS an interesting alternative. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3204 / 3211
页数:8
相关论文
共 11 条
[1]  
ACGIH, 1998, IND VENT MAN REC PRA, V23rd
[2]  
ARENS AD, 2000, THESIS MIT CAMBRIDGE
[3]  
*ASHRAE, 2002, HDB ASHRAE
[4]   Chilled ceiling and displacement ventilation system for energy savings: A case study [J].
Ghali, K. ;
Ghaddar, N. ;
Ayoub, M. .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (08) :743-759
[5]   Theoretical and experimental investigation of impinging jet ventilation and comparison with wall displacement ventilation [J].
Karimipanah, T ;
Awbi, HB .
BUILDING AND ENVIRONMENT, 2002, 37 (12) :1329-1342
[6]  
MUNDT E, 1995, BUILD ENVIRON, V30, P29
[7]   A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems [J].
Novoselac, A ;
Srebric, J .
ENERGY AND BUILDINGS, 2002, 34 (05) :497-509
[8]   The effect of location of a convective heat source on displacement ventilation: CFD study [J].
Park, HJ ;
Holland, D .
BUILDING AND ENVIRONMENT, 2001, 36 (07) :883-889
[9]   A nodal model for displacement ventilation and chilled ceiling systems in office spaces [J].
Rees, SJ ;
Haves, P .
BUILDING AND ENVIRONMENT, 2001, 36 (06) :753-762
[10]  
Skistad H., 1994, Displacement Ventilation