Parent and neutral loss monitoring on a quadrupole ion trap mass spectrometer: Screening of acylcarnitines in complex mixtures

被引:29
作者
McClellan, JE [1 ]
Quarmby, ST [1 ]
Yost, RA [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
关键词
D O I
10.1021/ac026073d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and practical technique for performing both parent and neutral loss (P&NL) monitoring experiments on a quadrupole ion trap mass spectrometer is presented. This technique is capable of performing scans analogous to the parent and neutral loss scans routinely applied on tandem-in-space instruments, and allows for the screening of a sample to detect analytes of a specific compound class on a chromatographic time-scale. Acylcarnitines were chosen as the model compound class to demonstrate the analytical utility of P&NL monitoring because of their amenability to electrospray ionization (ESI), their unique and informative MS/MS fragmentation pattern, and their importance in biological functions. The [M + H](+) ions of all acylcarnitines dissociate to produce neutral losses of 59 and 161 amu and common product ions at m/z 60, 85, and 144. Both the neutral loss monitoring of 59 amu and the parent ion monitoring of m/z 85 are shown to be capable of identifying acylcarnitine [M + H](+) ions in a synthetic mixture and spiked pig plasma. The neutral loss monitoring of 59 amu is successful in detecting acylcarnitines in an unspiked pig plasma sample.
引用
收藏
页码:5799 / 5806
页数:8
相关论文
共 25 条
[1]   CARNITINE [J].
BIEBER, LL .
ANNUAL REVIEW OF BIOCHEMISTRY, 1988, 57 :261-283
[2]  
BORUM PR, 1985, CLIN ASPECTS HUMAN C, P157
[3]  
CARLSON SM, 1995, P 43 ASMS C MASS SPE, P537
[4]  
Chace DH, 1997, CLIN CHEM, V43, P2106
[5]   ROLE OF CARNITINE IN HUMAN-NUTRITION [J].
FELLER, AG ;
RUDMAN, D .
JOURNAL OF NUTRITION, 1988, 118 (05) :541-547
[6]   TANDEM MASS-SPECTROMETRY - MULTISECTOR MAGNETIC INSTRUMENTS [J].
GROSS, ML .
METHODS IN ENZYMOLOGY, 1990, 193 :131-153
[7]   Determination of carnitine and acylcarnitines in biological samples by capillary electrophoresis-mass spectrometry [J].
Heinig, K ;
Henion, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 735 (02) :171-188
[8]  
Johnson J. V., 1985, ANAL CHEM, V57, P758
[9]   MS MS PARENT SCANS ON A QUADRUPOLE ION TRAP MASS-SPECTROMETER BY SIMULTANEOUS RESONANT EXCITATION OF MULTIPLE IONS [J].
JOHNSON, JV ;
PEDDER, RE ;
YOST, RA .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 106 :197-212
[10]   TANDEM-IN-SPACE AND TANDEM-IN-TIME MASS-SPECTROMETRY - TRIPLE QUADRUPOLES AND QUADRUPOLE ION TRAPS [J].
JOHNSON, JV ;
YOST, RA ;
KELLEY, PE ;
BRADFORD, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2162-2172