Glucose biosensing based on the highly efficient immobilization of glucose oxidase on a Prussian blue modified nanostructured Au surface

被引:45
作者
Ahmadalinezhad, Asieh [1 ]
Kafi, A. K. M. [1 ]
Chen, Aicheng [1 ]
机构
[1] Lakehead Univ, Dept Chem, Thunder Bay, ON P7B 5E1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Glucose; Nanostructured Au; Glucose oxidase; Biosensor; Prussian blue; GOLD NANOPARTICLES; ELECTRODE; SENSOR; POLYMER;
D O I
10.1016/j.elecom.2009.08.048
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report on a novel glucose biosensor based on the immobilization of glucose oxidase (GOx) on a Prussian blue modified nanoporous gold surface. The amperometric glucose biosensor fabricated in this study exhibits a fast response and the very low detection limit of 2.5 mu M glucose. The sensitivity of the biosensor was found to be very high, 177 mu A/mM; the apparent Michaelis-Menten constant is calculated to be 2.1 mM. In addition, the biosensor has good reproducibility and remains stable over 60 days. The anti-interference ability of the biosensor was also assessed, showing little interference from possible interferents such as ascorbic acid (AA), acetaminophen (AP) and uric acid (UA). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2048 / 2051
页数:4
相关论文
共 29 条
[1]   Development of a carbon nanotube paste electrode osmium polymer-mediated biosensor for determination of glucose in alcoholic beverages [J].
Antiochia, Riccarda ;
Gorton, Lo .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) :2611-2617
[2]   High performance glucose biosensor based on the immobilization of glucose oxidase onto modified titania nanotube arrays [J].
Benvenuto, Paul ;
Kafi, A. K. M. ;
Chen, Aicheng .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 627 (1-2) :76-81
[3]   Abrasive Stripping Voltammetry in Room Temperature Ionic Liquids [J].
Chen, Aicheng ;
Rogers, Emma I. ;
Compton, Richard G. .
ELECTROANALYSIS, 2009, 21 (01) :29-35
[4]   Simultaneous measurements of glucose, glutamine, ammonia, lactate, and glutamate in aqueous solutions by near-infrared spectroscopy [J].
Chung, H ;
Arnold, MA ;
Rhiel, M ;
Murhammer, DW .
APPLIED SPECTROSCOPY, 1996, 50 (02) :270-276
[5]   HPLC STUDIES ON THE DEGRADATION PROFILES OF GLUCOSE 5-PERCENT SOLUTIONS SUBJECTED TO HEAT STERILIZATION IN A MICROPROCESSOR-CONTROLLED AUTOCLAVE [J].
COOK, AP ;
MACLEOD, TM ;
APPLETON, JD ;
FELL, AF .
JOURNAL OF CLINICAL PHARMACY AND THERAPEUTICS, 1989, 14 (03) :189-195
[6]   Multiple-Reaction Monitoring Liquid Chromatography Mass Spectrometry for Monosaccharide Compositional Analysis of Glycoproteins [J].
Hammad, Loubna A. ;
Saleh, Marwa M. ;
Novotny, Milos V. ;
Mechref, Yehia .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (06) :1224-1234
[7]   Amperometric glucose sensor based on platinum-iridium nanomaterials [J].
Holt-Hindle, Peter ;
Nigro, Samantha ;
Asmussen, Matt ;
Chen, Aicheng .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (10) :1438-1441
[8]  
Ju HX, 1998, ELECTROANAL, V10, P541, DOI 10.1002/(SICI)1521-4109(199807)10:8<541::AID-ELAN541>3.3.CO
[9]  
2-A
[10]   Carbon nanotube-based electrochemical sensors for quantifying the 'heat' of chilli peppers: the adsorptive stripping voltammetric determination of capsaicin [J].
Kachoosangi, Roohollah Torabi ;
Wildgoose, Gregory G. ;
Compton, Richard G. .
ANALYST, 2008, 133 (07) :888-895