Preconcentration and determination of lead, cadmium and nickel from water samples using a polyethylene glycol dye immobilized on poly(hydroxyethylmethacrylate) microspheres

被引:41
作者
Arpa, Cigdem [1 ]
Bektas, Sema [1 ]
机构
[1] Hacettepe Univ, Dept Chem, TR-06532 Ankara, Turkey
关键词
SOLID-PHASE EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; AMBERLITE XAD-2; METAL-IONS; CHELATING RESIN; ENRICHMENT; SEPARATION; SORPTION; REMOVAL; COPPER;
D O I
10.2116/analsci.22.1025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and sensitive preconcentration analysis-atomic absorption spectrometric procedure is described for the determination of lead, cadmium and nickel. The method is based upon on-line preconcentration of metal ions on a minicolumn of Cibacron Blue F3-GA immobilized on poly(hydroxyethylmethacrylate), poly(HEMA). The enrichment factors obtained were 42 for lead, 52 for cadmium and 63 for nickel (sample volume 10 mL and sample flow rate 5 mL/min). The relative standard deviations (n=10), in 10 mL sample solutions containing 100 mu g/L Pb2+, 10 mu g/L Cd2+ and 100 mu g/L Ni2+ were 8.9, 3.7 and 3.5%, respectively. The limits of detection (blank+3s) (n=10), were found to be 12.01 mu g/L for Pb2+, 1.34 mu g/L for Cd2+ and 28.73 mu g/L for Ni2+. The accuracy of the system was checked with certified and tap water samples spiked with known amounts of metal ions. No significant difference was found between the achieved results and the certified values.
引用
收藏
页码:1025 / 1029
页数:5
相关论文
共 27 条
[1]   Adsorption of heavy metal ions on polyhydroxyethylmethacrylate microbeads carrying Cibacron Blue F3GA [J].
Arpa, Ç ;
Alim, C ;
Bektas, S ;
Cenç, Ö ;
Denizli, A .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2001, 176 (2-3) :225-232
[2]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[3]   Chromium(III) removal by poly(ethyleneimine) granular sorbents made by a new process of templated gel filling [J].
Chanda, M ;
Rempel, GL .
REACTIVE & FUNCTIONAL POLYMERS, 1997, 35 (03) :197-207
[4]   Determination of cadmium, copper, lead and zinc in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) :215-222
[5]   Cibacron Blue F3GA-incorporated macroporous poly(2-hydroxyethyl methacrylate) affinity membranes for heavy metal removal [J].
Denizli, A ;
Salih, B ;
Arica, MY ;
Kesenci, K ;
Hasirci, V ;
Piskin, E .
JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (02) :217-226
[6]   Novel dye-attached macroporous films for cadmium, zinc and lead sorption: Alkali Blue 6B-attached macroporous poly(2-hydroxyethyl methacrylate) [J].
Denizli, A ;
Kesenci, K ;
Arica, MY ;
Salih, B ;
Hasirci, V ;
Piskin, E .
TALANTA, 1998, 46 (04) :551-558
[7]   Selective preconcentration of ultra trace copper(II) using octadecyl silica membrane disks modified by a recently synthesized glyoxime derivative [J].
Ghiasvand, AR ;
Ghaderi, R ;
Kakanejadifard, A .
TALANTA, 2004, 62 (02) :287-292
[8]   Synthesis of spherical macroporous epoxy-dicyandiamide chelating resin and properties of concentration and separation of trace metal ions from samples [J].
Gong, BL ;
Li, XQ ;
Wang, FR ;
Chang, XJ .
TALANTA, 2000, 52 (02) :217-223
[9]  
Kim JS, 1999, SEPAR SCI TECHNOL, V34, P2957
[10]   Metal ion enrichment with Amberlite XAD-2 functionalized with Tiron: analytical applications [J].
Kumar, M ;
Rathore, DPS ;
Singh, AK .
ANALYST, 2000, 125 (06) :1221-1226