Determination of the substance P receptor antagonist CP-122,721 in plasma by narrow-bore high-performance liquid chromatography ionspray tandem mass spectrometry

被引:5
作者
Kamel, A [1 ]
Prakash, C [1 ]
机构
[1] PFIZER INC,DIV CENT RES,DEPT DRUG METAB,GROTON,CT 06340
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 700卷 / 1-2期
关键词
substance P; CP-122,721;
D O I
10.1016/S0378-4347(97)00315-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, highly sensitive and specific LC-MS-MS assay was developed for the determination of CP-122,721 (I) in rat and human plasma. I and a structural analog, CP-129,943 (II, internal standard), were extracted from plasma with methyl tert.-butyl ether (MTBE). The dried MTBE extracts were reconstituted and analyzed using a narrow-bore (2.1 mm I.D.) YMC basic HPLC column and a mobile phase of acetonitrile-20 mM ammonium acetate, pH 5 (50:50, v/v). Column effluents were monitored by ionspray tandem mass spectrometry. Multiple reaction monitoring (MRM) using the parent to product ion combinations of mit 381-->205 and 395-->219 was used to quantitate I and LT, respectively. The assay exhibited a linear dynamic range of 0.2-100 ng/ml. Absolute recoveries from plasma were above 80% for both I and II. The precision and accuracy values for the method were within +/-3 and +/-9%, respectively. Sample analysis times were less than 5 min from one injection to the next. The assay has proved to be applicable to the pharmacokinetic study of I in rats. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 17 条
[1]   HIGH-SPEED LIQUID-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY FOR THE DETERMINATION OF DRUGS IN BIOLOGICAL SAMPLES [J].
COVEY, TR ;
LEE, ED ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1986, 58 (12) :2453-2460
[2]   VAPOR-PHASE SILYLATION OF LABORATORY GLASSWARE [J].
FENIMORE, DC ;
DAVIS, CM ;
WHITFORD, JH ;
HARRINGTON, CA .
ANALYTICAL CHEMISTRY, 1976, 48 (14) :2289-2290
[3]   ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
SCIENCE, 1989, 246 (4926) :64-71
[4]   QUANTITATIVE-ANALYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY - THE DETERMINATION OF THE RENIN INHIBITOR CP-80,794 IN HUMAN SERUM [J].
FOUDA, H ;
NOCERINI, M ;
SCHNEIDER, R ;
GEDUTIS, C .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1991, 2 (02) :164-167
[5]   DETERMINATION OF L-654,066, A NEW 5-ALPHA-REDUCTASE INHIBITOR IN PLASMA BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GILBERT, JD ;
OLAH, TV ;
BARRISH, A ;
GREBER, TF .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (07) :341-346
[6]   DETERMINATION OF L-365,260, A NEW CHOLECYSTOKININ RECEPTOR (CCK-B) ANTAGONIST, IN PLASMA BY LIQUID-CHROMATOGRAPHY ATMOSPHERIC-PRESSURE CHEMICAL IONIZATION MASS-SPECTROMETRY [J].
GILBERT, JD ;
HAND, EL ;
YUAN, AS ;
OLAH, TV ;
COVEY, TR .
BIOLOGICAL MASS SPECTROMETRY, 1992, 21 (02) :63-68
[7]   Broad spectrum antiemetic effects of CP-122,721, a tachykinin NK1 receptor antagonist, in ferrets [J].
Gonsalves, S ;
Watson, J ;
Ashton, C .
EUROPEAN JOURNAL OF PHARMACOLOGY, 1996, 305 (1-3) :181-185
[8]  
KAMEL A, 1997, P 45 AM SOC MASS SPE
[9]  
Lau YY, 1996, J CHROMATOGR B, V683, P209
[10]  
McLean S, 1996, J PHARMACOL EXP THER, V277, P900