Voltage Balancing Control for a Three-Level Diode-Clamped Converter in a Medium-Voltage Transformerless Hybrid Active Filter

被引:95
作者
Akagi, Hirofumi [1 ]
Hatada, Takaaki [1 ]
机构
[1] Tokyo Inst Technol, Dept Elect & Elect Engn, Tokyo 1528552, Japan
关键词
Active filters; diode rectifiers; harmonics; hybrid filters; passive filters; three-level converters; POWER-SYSTEMS; HARMONIC COMPENSATION; MODULATION INDEX; PERFORMANCE; RECTIFIER; INVERTER; DESIGN;
D O I
10.1109/TPEL.2009.2012528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses a transformerless hybrid active filter integrated into the 6.6-kV, I-MW adjustable-speed motor drive having a three-phase diode rectifier at the front end. The hybrid filter consists of an active filter using a three-level diode-clamped pulsewidth modulator converter rated at 60 kVA, and a 250-kVA passive filter tuned to the seventh harmonic frequency. They are directly connected in series without a transformer. This circuit configuration enables one to use 1.2-kV insulated gate bipolar transistors because the dc voltage of the three-level converter is 1.32 kV (20% of 6.6 kV). Voltage balancing control characterized by superimposing a sixth harmonic zero-sequence voltage on the active filter voltage reference in each phase is introduced to the three-level converter with triangle carrier modulation. Experimental waveforms obtained from a 400-V, 15-kW downscaled system verify the viability and effectiveness of the proposed hybrid filter, keeping the two dc capacitor voltages well-balanced.
引用
收藏
页码:571 / 579
页数:9
相关论文
共 31 条
[1]  
Aburto V, 1997, IEEE POWER ELECTRON, P1121, DOI 10.1109/PESC.1997.616889
[2]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[3]   Active harmonic filters [J].
Akagi, H .
PROCEEDINGS OF THE IEEE, 2005, 93 (12) :2128-2141
[4]  
Akagi H, 2003, IEEE IND APPLIC SOC, P1195
[5]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[6]  
Akagi H., 2007, INSTANTANEOUS POWER
[7]   Harmonic filtering of high-power 12-pulse rectifier loads with a selective hybrid filter system [J].
Basic, D ;
Ramsden, VS ;
Muttik, PK .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2001, 48 (06) :1118-1127
[8]   Hybrid solutions for improving passive filter performance in high power applications [J].
Bhattacharya, S ;
Cheng, PT ;
Divan, DM .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (03) :732-747
[9]   Optimal pulse-width modulation for three-level inverters [J].
Brückner, T ;
Holmes, DG .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (01) :82-89
[10]   A comprehensive study of neutral-point voltage balancing problem in three-level neutral-point-clamped voltage source PWM inverters [J].
Celanovic, N ;
Boroyevich, D .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (02) :242-249