Detection procedures of ultrasound contrast agents

被引:135
作者
de Jong, N [1 ]
Frinking, PJA
Bouakaz, A
Ten Cate, FJ
机构
[1] Erasmus Univ, Ctr Heart, Dept Cardiol & Expt Echocardiog, Rotterdam, Netherlands
[2] ICIN, Utrecht, Netherlands
关键词
contrast agents; detection methods; diagnosis; medical; ultrasound;
D O I
10.1016/S0041-624X(99)00071-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In the early days, it was believed that ultrasound contrast agents (UCA) could be sufficiently detected and imaged with the conventional imaging methods nowadays referred to as fundamental imaging. Newer imaging techniques proved to be more sensitive and are based on specific properties of the UCA. In general, these new characteristics involve non-linear and transient characteristics of contrast agents that appear at the high end of the diagnostic acoustic intensity. Imaging modalities used today for UCA are, besides fundamental imaging, second harmonic imaging, power Doppler, harmonic power Doppler, pulse inversion and pulse inversion Doppler, multi-pulse imaging and subharmonic imaging. Although the results of conventional second harmonic imaging are still not optimal for perfusion imaging applications, in combination with Doppler techniques (colour Doppler, power Doppler) it is one of the most sensitive techniques currently available in terms of agent-to-tissue ratio. Further improvements in current and future detection methods demand a complete understanding of the ultrasound-UCA interaction. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 12 条
[1]   Rationale and derivation of Mi and Ti - A review [J].
Abbott, JG .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (03) :431-441
[2]   Scattering properties of encapsulated gas bubbles at high ultrasound pressures [J].
Frinking, PJA ;
de Jong, N ;
Céspedes, EI .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1999, 105 (03) :1989-1996
[3]  
FRINKING PJA, 1998, IEEE ULTR S SEND JAP
[4]   Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border [J].
Kasprzak, JD ;
Paelinck, B ;
Ten Cate, FJ ;
Vletter, WB ;
de Jong, N ;
Poldermans, D ;
Elhendy, A ;
Bouakaz, A ;
Roelandt, JRTC .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (02) :211-217
[5]  
KIRKHORN J, 1999, 4 HEART CTR EUR S UL
[6]   Experimental observation of subharmonic oscillations in Infoson bubbles [J].
Lotsberg, O ;
Hovem, JM ;
Aksum, B .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1996, 99 (03) :1366-1369
[7]   CONTRAST AGENTS IN DIAGNOSTIC ULTRASOUND [J].
OPHIR, J ;
PARKER, KJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (04) :319-333
[8]  
POWERS JE, 1997, ADV ECHO IMAGING USI, P139
[9]   Advantages of subharmonic over second harmonic backscatter for contrast-to-tissue echo enhancement [J].
Shankar, PM ;
Krishna, PD ;
Newhouse, VL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :395-399
[10]   Pressure dependence of subharmonic signals from contrast microbubbles [J].
Shi, WT ;
Forsberg, F ;
Raichlen, JS ;
Needleman, L ;
Goldberg, BB .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02) :275-283