In vivo efficacy of a bioartificial liver in improving spontaneous recovery from fulminant hepatic failure:: A controlled study in pigs

被引:22
作者
Cuervas-Mons, V
Colás, A
Rivera, JA
Prados, E
机构
[1] Puerta Hierro Clin, Liver Transplant Unit, Madrid, Spain
[2] Puerta Hierro Clin, Dept Surg, Madrid, Spain
关键词
D O I
10.1097/00007890-200002150-00005
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Bioartificial liver may be useful as a bridge to liver transplantation but there are no data of its efficacy in successfully bridging to spontaneous recovery: in fulminant hepatic failure. The aim of our study was to evaluate the efficacy of a bioartificial liver in increasing the spontaneous recovery of pigs with hepatic failure. Methods. The bioartificial liver consisted in a semipermeable: dialyzer with 0.6x10(9) cryopreserved allogenic hepatocytes. Hepatic failure was induced by portacaval shunt plus 70% hepatectomy and 1 hour occlusion of:the hepatic artery, Forty-one pigs were distributed 24 hr after liver failure induction to a group treated with the bioartificial liver (4 hr daily) until recovery or death (n=16), or to a control group (n=25), Intracranial pressure was monitored in 18 additional pigs, before and 4 hr after treatment with the bioartificial liver with (n=12) or without hepatocytes (n=6). Results. Fifteen days after induction of hepatic failure, 44% of the treated animals had survived and recovered from liver failure versus 22% controls (P=0.030). Intracranial pressure decreased from 13.13+/-5.1 to 7.19+/-2.06 mmHg (P=0.02) in treated animals, and remained unchanged in sham-treated animals (14.08+/-1.92 to 12.54+/-3.82, ns). Conclusions. Bioartificial liver increases survival and allows spontaneous recovery in pigs with fulminant hepatic failure.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 34 条
[1]  
BARRERA P, 1992, LYMPHOKINE CYTOK RES, V11, P99
[2]  
BELLE HB, 1994, CLIN TRANSPLANT, P19
[3]  
BONE RC, 1993, JAMA-J AM MED ASSOC, V270, P975
[4]  
*CAN ORG REPL REG, 1992, 256 CAN I HLTH INF C
[5]   Clinical experience with a porcine hepatocyte-based liver support system [J].
Chen, SC ;
Hewitt, WR ;
Watanabe, FD ;
Eguchi, S ;
Kahaku, E ;
Middleton, Y ;
Rozga, J ;
Demetriou, AA .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (11) :664-669
[6]  
CUERVASMONS V, 1983, REV ESP ENFERM APAR, V64, P389
[7]  
DEMETRIOU AA, 1992, ARTIFICIAL LIVER SUP, P283
[8]   Pilot-controlled trial of the extracorporeal liver assist device in acute liver failure [J].
Ellis, AJ ;
Hughes, RD ;
Wendon, JA ;
Dunne, J ;
Langley, PG ;
Kelly, JH ;
Gislason, GT ;
Sussman, NL ;
Williams, R .
HEPATOLOGY, 1996, 24 (06) :1446-1451
[9]  
EMON JC, 1989, GASTROENTEROLOGY, V21, P2435
[10]  
*EUR LIV TRANSPL R, 1997, EUR LIV TRANSPL ASS