Non-invasive 3-D patient registration for image-guided skull base surgery

被引:9
作者
Westermann, B
Hauser, R
机构
来源
COMPUTERS & GRAPHICS-UK | 1996年 / 20卷 / 06期
关键词
D O I
10.1016/S0097-8493(96)00049-0
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
Image-guided, computer-assisted surgery systems require a common reference between the preoperative image data and the corresponding patient pathology. Therefore, the problem of an accurate and reliable 3-D patient registration and referencing has to be solved. Considering that during image data acquisition patient misalignment and movement can arise in three dimensions, an automatic image registration method must be based on a three-dimensional approach. The method presented in this paper provides accurate 3-D patient registration for correction of these movement errors during data acquisition and active patient referencing to update the position of the head during surgery. Experimental data concerning the accuracy of repeated positionings of our patient registration and reference system demonstrated a high degree of accuracy with mean spatial errors of 0.82 mm +/- 0.31 mm in a plastic skull and 1.56 +/- 0.76 mm in patients, respectively. Results suggest that non-invasive 3-D patient registration for image-guided surgery may be a precise and useful method for computer-assisted identification of anatomical structures. Copyright (C) 1996 Elsevier Science Ltd.
引用
收藏
页码:793 / 799
页数:7
相关论文
共 15 条
  • [1] ANON JB, 1994, LARYNGOSCOPE, V104, P901
  • [2] A NEW MODEL FOR NONINVASIVE, REPRODUCIBLE FIXATION OF A STEREOTAXIC FRAME USING AN ORTHODONTIC RESIN PLATE
    CARINI, S
    CALCAGNO, E
    TORTORIDONATI, P
    ANDREUSSI, L
    [J]. ACTA NEUROCHIRURGICA, 1992, 118 (3-4) : 159 - 161
  • [3] FRACTIONATED RADIOTHERAPY OF SMALL INOPERABLE LESIONS OF THE BRAIN USING A NONINVASIVE STEREOTAXIC FRAME
    DELANNES, M
    DALY, NJ
    BONNET, J
    SABATIER, J
    TREMOULET, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (03): : 749 - 755
  • [4] GILL SS, 1989, J NEUROL NEUROSUR PS, V52, P1460
  • [5] HARIZ MI, 1986, APPL NEUROPHYSIOL, V49, P336
  • [6] A NONINVASIVE, REATTACHABLE SKULL FIDUCIAL MARKER SYSTEM - TECHNICAL NOTE
    HOWARD, MA
    DOBBS, MB
    SIMONSON, TM
    LAVELLE, WE
    GRANNER, MA
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 372 - 376
  • [7] KAVANAGH KT, 1994, LARYNGOSCOPE, V104, P283
  • [8] COMPUTER-ASSISTED LOCALIZER FOR PLANNING OF SURGERY AND INTRAOPERATIVE ORIENTATION
    LABORDE, G
    GILSBACH, J
    HARDERS, A
    KLIMEK, L
    MOESGES, R
    KRYBUS, W
    [J]. ACTA NEUROCHIRURGICA, 1992, 119 (1-4) : 166 - 170
  • [9] VOXEL-BASED LOCALIZATION IN FRAME-BASED AND FRAMELESS STEREOTAXY AND ITS ACCURACY
    LEMIEUX, L
    KITCHEN, ND
    HUGHES, SW
    THOMAS, DGT
    [J]. MEDICAL PHYSICS, 1994, 21 (08) : 1301 - 1310
  • [10] NITSCHE N, 1993, OTORHINOLARYNGOL NOV, V3, P173