An improved electronic microarray-based diagnostic assay for identification of MEFV mutations

被引:22
作者
Moutereau, S
Narwa, R
Matheron, C
Vongmany, N
Simon, E
Goossens, M
机构
[1] Hop Henri Mondor, Serv Biochim & Genet Mol, F-94010 Creteil, France
[2] Hop Henri Mondor, INSERM, French Inst Hlth & Med Res, U468, F-94010 Creteil, France
[3] Hop Henri Mondor, Hematol Lab, F-94010 Creteil, France
[4] AP HP, CEDIT, Paris, France
关键词
mutation detection; genotyping; microarray; universal oligonucleotides; electronic hybridization; MEFV; F5; F2; FMF;
D O I
10.1002/humu.20045
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Recent technological advances, such as DNA chip devices that allow automated, high-throughput genotyping, promise to considerably improve the detection capability of single-nucleotide polymorphisms (SNPs) in clinically relevant genes. We used the NanoChip(R) Molecular Biology Workstation (Nanogen, www.nanogen. com) and recently introduced microelectronic array technology to develop a detection method for the more frequent mutations involved in familial Mediterranean fever (FMF), an amosomal recessive disease that affects several ethnic groups in the Mediterranean population, whose early diagnosis is crucial if severe complications are to be prevented. We adapted the previously described Nanogen procedures to FMF mutation analysis, introducing modifications that notably improve the technique. First, as the original procedure makes use of costly dye-tagged reporter sequences, we devised a universal reporter strategy, which was first evaluated and validated on the robust, previously established factor V Leiden and factor II (prothrombin) NanoChip diagnostic assays. FMF (MEFV), factor V (F5), and factor II (F2) genotypes identified using this improved system were totally concordant with results of other genotyping methods (denaturing gradient gel electrophoresis [DGGE], SSCP, and RFLP analysis). Second, we showed that the target sequences loaded on the NanoChip cartridges can be rehybridized several times in a highly reproducible manner, allowing sequential analysis of mutations. Thus, we devised a strategy that allows us to monitor the possible interference of additional mutations or SNPs at probe or stabilizer sequences. Finally, a comparative cost per sample analysis demonstrates that the accurate and reproducible FMF mutation detection assay we developed can be readily implemented in the clinical laboratory setting at reasonable expense. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:621 / 628
页数:8
相关论文
共 19 条
[1]  
Aksentijevich I, 1997, CELL, V90, P797
[2]  
Bernot A, 1997, NAT GENET, V17, P25
[3]   MEFV-gene analysis in Armenian patients with familial Mediterranean fever:: Diagnostic value and unfavorable renal prognosis of the M694V homozygous genotype -: Genetic and therapeutic implications [J].
Cazeneuve, C ;
Sarkisian, T ;
Pêcheux, C ;
Dervichian, M ;
Nédelec, B ;
Reinert, P ;
Ayvazyan, A ;
Kouyoumdjian, JC ;
Ajrapetyan, H ;
Delpech, M ;
Goossens, M ;
Dodé, C ;
Grateau, G ;
Amselem, S .
AMERICAN JOURNAL OF HUMAN GENETICS, 1999, 65 (01) :88-97
[4]  
CHASE JJ, 2003, MOL CELL, V11, P591
[5]   Development of a universal probe for electronic microarray and its application in characterization of the Staphylococcus aureus po/C gene [J].
Cooper, KLF ;
Goering, RV .
JOURNAL OF MOLECULAR DIAGNOSTICS, 2003, 5 (01) :28-33
[6]   INFEVERS:: the Registry for FMF and hereditary inflammatory disorders mutations [J].
de Menthière, CS ;
Terrière, S ;
Pugnère, D ;
Ruiz, M ;
Demaille, J ;
Touitou, I .
NUCLEIC ACIDS RESEARCH, 2003, 31 (01) :282-285
[7]  
Dodé C, 2000, AM J MED GENET, V92, P241, DOI 10.1002/(SICI)1096-8628(20000605)92:4<241::AID-AJMG3>3.0.CO
[8]  
2-G
[9]  
Evans JG, 2002, CLIN CHEM, V48, P1406
[10]   A RAPID SCREENING METHOD FOR THE FACTOR-V ARG506-]GLN MUTATION [J].
GANDRILLE, S ;
ALHENCGELAS, M ;
AIACH, M .
BLOOD COAGULATION & FIBRINOLYSIS, 1995, 6 (03) :245-248