Comparison and modification of two cerebral protection devices used for carotid angioplasty:: In vitro experiment

被引:19
作者
Müller-Hülsbeck, S
Grimm, J
Liess, C
Hedderich, J
Bergmeyer, M
Heller, M
机构
[1] Univ Hosp Kiel, Dept Radiol, D-24105 Kiel, Germany
[2] Univ Hosp Kiel, Dept Phys Med, D-24105 Kiel, Germany
[3] Univ Hosp Kiel, Dept Med Stat, D-24105 Kiel, Germany
关键词
carotid arteries; stenosis or obstruction; interventional procedures; complications; experimental studies;
D O I
10.1148/radiol.2251011008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The effectiveness of two basic cerebral protection devices designed for carotid angioplasty with and without additional aspiration techniques was compared in an in vitro model. During carotid angioplasty, embolization was simulated by injecting polyvinyl alcohol particles of different sizes into the model system: None of the tested devices, all of,which were positioned in the internal carotid artery, was able to completely prevent embolization. In the internal carotid artery, the rate of particle capture did not vary among protection devices. However, embolization into the external carotid artery was more frequent with use of the GuideWire, as compared with that with use of the Angioguard. (C) RSNA, 2002.
引用
收藏
页码:289 / 294
页数:6
相关论文
共 30 条
[1]   Balloon-protected carotid angioplasty [J].
Albuquerque, FC ;
Teitelbaum, GP ;
Lavine, SD ;
Larsen, DW ;
Giannotta, SL .
NEUROSURGERY, 2000, 46 (04) :918-921
[2]  
[Anonymous], 1994, STROKE, V25, P2523
[3]   Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis [J].
Barnett, HJM ;
Taylor, W ;
Eliasziw, M ;
Fox, AJ ;
Ferguson, GG ;
Haynes, RB ;
Rankin, RN ;
Clagett, GP ;
Hachinski, VC ;
Sackett, DL ;
Thorpe, KE ;
Meldrum, HE ;
Spence, JD .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (20) :1415-1425
[4]   Transcranial Doppler detection of microemboli during percutaneous transluminal coronary angioplasty [J].
Bladin, CF ;
Bingham, L ;
Grigg, L ;
Yapanis, AG ;
Gerraty, R ;
Davis, SM .
STROKE, 1998, 29 (11) :2367-2370
[5]   Comparison of hemodynamic cerebral ischemia and microembolic signals detected during carotid endarterectomy and carotid angioplasty [J].
Crawley, F ;
Clifton, A ;
Buckenham, T ;
Loosemore, T ;
Taylor, RS ;
Brown, MM .
STROKE, 1997, 28 (12) :2460-2464
[6]  
DERDEYN CP, 1995, AM J NEURORADIOL, V16, P1335
[7]  
Diethrich EB, 1996, J ENDOVASC SURG, V3, P42, DOI 10.1583/1074-6218(1996)003<0042:SITCAI>2.0.CO
[8]  
2
[9]   RHEOLYTIC CATHETER FOR PERCUTANEOUS REMOVAL OF THROMBUS [J].
DRASLER, WJ ;
JENSON, ML ;
WILSON, GJ ;
THIELEN, JM ;
PROTONOTARIOS, EI ;
DUTCHER, RG ;
POSSIS, ZC .
RADIOLOGY, 1992, 182 (01) :263-267
[10]  
GILLILAN LA, 1961, ARCH OPHTHALMOL-CHIC, V65, P684