High-resolution, spin-echo BOLD, and CBF AM at 4 and 7 T

被引:114
作者
Duong, TQ [1 ]
Yacoub, E [1 ]
Adriany, G [1 ]
Hu, XP [1 ]
Ugurbil, K [1 ]
Vaughan, JT [1 ]
Merkle, H [1 ]
Kim, SG [1 ]
机构
[1] Univ Minnesota, Sch Med, Ctr Magnet Resonance Res, Dept Radiol, Minneapolis, MN 55455 USA
关键词
high resolution; spatial specificity; spin echo; brain mapping; FAIR; BOLD; high fields;
D O I
10.1002/mrm.10252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With growing interest in noninvasive mapping of columnar organization and other small functional structures in the brain, achieving high spatial resolution and specificity in fMRI is of critical importance. We implemented a simple method for BOLD and perfusion fMRI with high spatial resolution and specificity. Increased spatial resolution was achieved by selectively exciting a slab of interest along the phase-encoding direction for EPI, resulting in a reduced FOV and number of phase-encoding steps. Improved spatial specificity was achieved by using SE EPI acquisition at high fields, where it is predominantly sensitive to signal changes in the microvasculature. Robust SE BOLD and perfusion fMRI were obtained with a nominal in-plane resolution up to 0.5 x 0.5 mm(2) at 7 and 4 Tesla, and were highly reproducible under repeated measures. This methodology enables high-resolution and high-specificity studies of functional topography in the millimeter to submillimeter spatial scales of the human brain. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:589 / 593
页数:5
相关论文
共 26 条
[1]   MB-guided biopsy using a T2-weighted single-shot zoom imaging sequence (Local Look technique) [J].
Buecker, A ;
Adam, G ;
Neuerburg, JM ;
Glowinski, A ;
van Vaals, JJ ;
Guenther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :955-959
[2]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[3]  
DUONG T, 2001, P 9 ANN M ISMRM GLAS, P1253
[4]   Localized cerebral blood flow response at submillimeter columnar resolution [J].
Duong, TQ ;
Kim, DS ;
Ugurbil, K ;
Kim, SG .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2001, 98 (19) :10904-10909
[5]   INNER VOLUME MR IMAGING - TECHNICAL CONCEPTS AND THEIR APPLICATION [J].
FEINBERG, DA ;
HOENNINGER, JC ;
CROOKS, LE ;
KAUFMAN, L ;
WATTS, JC ;
ARAKAWA, M .
RADIOLOGY, 1985, 156 (03) :743-747
[6]   IMAGE-RECONSTRUCTION USING PROJECTION ONTO CONVEX-SETS, MODEL CONSTRAINTS, AND LINEAR PREDICTION-THEORY FOR THE REMOVAL OF PHASE, MOTION, AND GIBBS ARTIFACTS IN MAGNETIC-RESONANCE AND ULTRASOUND IMAGING [J].
HAACKE, EM ;
LIANG, ZP ;
BOADA, F .
OPTICAL ENGINEERING, 1990, 29 (05) :555-566
[7]   High-resolution fMRI using multislice partial k-space GR-EPI with cubic voxels [J].
Hyde, JS ;
Biswal, BB ;
Jesmanowicz, A .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :114-125
[8]  
Jovicich J, 1999, MAGNET RESON MED, V41, P871, DOI 10.1002/(SICI)1522-2594(199905)41:5<871::AID-MRM3>3.0.CO
[9]  
2-O
[10]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301