Determination of delorazepam in urine by solid-phase microextraction coupled to high performance liquid chromatography

被引:17
作者
Aresta, A [1 ]
Monaci, L [1 ]
Zambonin, CG [1 ]
机构
[1] Univ Bari, Dipartimento Chim, I-70100 Bari, Italy
关键词
delorazepam; solid-phase microextraction; desorption conditions;
D O I
10.1016/S0731-7085(02)00012-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An SPME-HPLC-UV method for the determination of delorazepam, a representative benzodiazepine, in spiked human urine samples was developed for the first time. The performances of two commercially available fibers, a carbowax/templated resin (Carbowax/TPR-100) and a polydimethylsiloxane/divinylbenzene (PDMS/DVB), were compared, indicating the latter as the most suitable for urine samples analysis. All the aspects influencing adsorption (extraction time, pH, temperature, salt addition) and desorption (desorption and injection time, desorption solvent mixture composition) of the analyte on the fiber have been investigated. In particular, short extraction times were necessary to reach the equilibrium and very short desorption times were employed. The procedure required simple sample pre-treatment and was able to detect 5 ng/ml in spiked urine, regardless of the complexity of the matrix. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:965 / 972
页数:8
相关论文
共 31 条
[1]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[2]   AUTOMATION AND OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION [J].
ARTHUR, CL ;
KILLAM, LM ;
BUCHHOLZ, KD ;
PAWLISZYN, J ;
BERG, JR .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1960-1966
[3]  
BECK O, 1992, CLIN CHEM, V38, P271
[4]   URINARY SCREENING FOR BENZODIAZEPINES WITH RADIORECEPTOR ASSAY - COMPARISON WITH EMIT(R) DAU BENZODIAZEPINE ASSAY AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BORGGAARD, B ;
JOERGENSEN, I .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1994, 18 (05) :243-246
[5]   POTENTIAL USE OF A RADIORECEPTOR ASSAY FOR THE DETERMINATION OF BENZODIAZEPINE COMPOUNDS IN SERUM [J].
BRUHWYLER, J ;
HASSOUN, A .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1993, 17 (07) :403-407
[6]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[7]   DEVELOPMENT AND PRELIMINARY APPLICATION OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF URINARY METABOLITES OF DIAZEPAM IN HUMANS [J].
CHIBA, K ;
HORII, H ;
CHIBA, T ;
KATO, Y ;
HIRANO, T ;
ISHIZAKI, T .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 668 (01) :77-84
[8]   Sudden death and benzodiazepines [J].
Drummer, OH ;
Ranson, DL .
AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 1996, 17 (04) :336-342
[9]   APPLICATION OF RADIORECEPTOR ASSAYS FOR SYSTEMATIC TOXICOLOGICAL ANALYSIS .1. PROCEDURES FOR RADIORECEPTOR ASSAYS FOR ANTIHISTAMINICS, ANTICHOLINERGICS AND BENZODIAZEPINES [J].
ENSING, K ;
BOSMAN, IJ ;
EGBERTS, ACG ;
FRANKE, JP ;
DEZEEUW, RA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (01) :53-58
[10]  
FITZGERALD RL, 1994, CLIN CHEM, V40, P373