The objective of this study was to develop a simple and sensitive LC method for the determination of creatine and creatinine in various creatine supplement formulations. The chromatographic system comprised of a LC-600 pump, SCL-6B system controller, and SPD-6AV detector (Shimadzu, Japan). The mobile phase consisted of 0.045 M ammonium sulfate in water. The chromatographic separation was achieved at ambient temperature on a Betabasic C-18 column (250 x 4.6 mm, Keystone Sci.). The flow rate was maintained at 0.75 ml/min and effluents are monitored at 205 nm. 4-(2-Aminoethyl)benzene sulfonamide was used as an internal standard (IS). This method required less than 7 min of chromatographic time. The standard curves were linear over the concentration range of 1-100 mug/ml for creatine and 2-100 mug/ml for creatinine, respectively. The relative standard deviations (RSD) for the within-day and day-to-day precision for creatine were within 1.0-4.6 and 2.2-4.7%, respectively. The RSD for the accuracy of creatine assay was in the range of 2.4-4.7%. The RSD values for the within-day precision, day-to-day precision and accuracy for creatinine validation were 1.7-4.4, 2.3-5.4 and 2.4-4.8%, respectively. This method was used to determine: (i) the creatine concentration in various marketed products; (ii) saturated solubility of various creatine salts; and (iii) stability of creatine in aqueous solution. In conclusion, a simple and sensitive LC method with UV detection was developed for the simultaneous determination of creatine and creatinine in formulations. Di-creatine citrate salt showed a higher aqueous solubility (at 25 degreesC) as compared to creatine and creatine monohydrate. Some of the over-the-counter (OTC) products tested contained a very low level of creatine in contrast to their label claim. Substantial conversion of creatine into creatinine was noticed in liquid formulation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:939 / 945
页数:7
相关论文
共 12 条
[1]  
DASH A, 2001, AAPS PHARMSCI S, V3, pM2249
[2]   REVERSE-PHASE ION-PAIRING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PHOSPHOCREATINE, CREATINE AND CREATININE IN EQUINE MUSCLE [J].
DUNNETT, M ;
HARRIS, RC ;
ORME, CE .
SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1991, 51 (02) :137-141
[3]   THE EFFECT OF CREATINE MONOHYDRATE INGESTION ON ANAEROBIC POWER INDEXES, MUSCULAR STRENGTH AND BODY-COMPOSITION [J].
EARNEST, CP ;
SNELL, PG ;
RODRIGUEZ, R ;
ALMADA, AL ;
MITCHELL, TL .
ACTA PHYSIOLOGICA SCANDINAVICA, 1995, 153 (02) :207-209
[4]  
EDGAR G, 1925, J AM CHEM SOC, V47, P1170
[5]   Carbohydrate ingestion augments creatine retention during creatine feeding in humans [J].
Green, AL ;
Simpson, EJ ;
Littlewood, JJ ;
MacDonald, IA ;
Greenhaff, PL .
ACTA PHYSIOLOGICA SCANDINAVICA, 1996, 158 (02) :195-202
[6]   INFLUENCE OF ORAL CREATINE SUPPLEMENTATION OF MUSCLE TORQUE DURING REPEATED BOUTS OF MAXIMAL VOLUNTARY EXERCISE IN MAN [J].
GREENHAFF, PL ;
CASEY, A ;
SHORT, AH ;
HARRIS, R ;
SODERLUND, K ;
HULTMAN, E .
CLINICAL SCIENCE, 1993, 84 (05) :565-571
[7]   SIMULTANEOUS DETERMINATION OF MYOCARDIAL ADENINE-NUCLEOTIDES AND CREATINE-PHOSPHATE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
HARMSEN, E ;
DETOMBE, PP ;
DEJONG, JW .
JOURNAL OF CHROMATOGRAPHY, 1982, 230 (01) :131-136
[8]  
JUENGING E, 1974, SCAND J CLIN LAB INV, V35, P87
[9]   DETERMINING THE LOWEST LIMIT OF RELIABLE ASSAY MEASUREMENT [J].
OPPENHEIMER, L ;
CAPIZZI, TP ;
WEPPELMAN, RM ;
MEHTA, H .
ANALYTICAL CHEMISTRY, 1983, 55 (04) :638-643
[10]  
TAKAAKI S, 1997, FISHERIES SCI, V63, P769