Upgrading patients with chronic defibrillator leads to a biventricular system and reducing patient risk: Contralateral LV lead placement

被引:13
作者
Fox, David J.
Petkar, Sanjiv
Davidson, Neil C.
Fitzpatrick, Adam P.
机构
[1] Manchester Royal Infirm, Manchester Heart Ctr, Manchester M13 9WL, Lancs, England
[2] Wythenshawe Hosp, NW Reg Cardiac Ctr, Manchester M23 9LT, Lancs, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2006年 / 29卷 / 09期
关键词
defibrillation-ICD; cardiac resynchronization therapy; contralateral left ventricular lead implant; SUBCLAVIAN VEIN;
D O I
10.1111/j.1540-8159.2006.00482.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Increasing numbers of patients with indwelling single- or dual-chamber internal cardioverter defibrillators (ICDs) will require upgrading of an existing system to a biventricular ICD providing cardiac resynchronization with back-up defibrillation. Upgrading, usually by the addition of a new left ventricular (IV) lead, can be technically challenging with central venous occlusion or stenosis often being the main obstacle to a successful procedure. We report a new technique of implanting a IV lead from the contralateral side to the existing ICD system to minimize the peri- and postoperative risk to the patient.
引用
收藏
页码:1025 / 1027
页数:3
相关论文
共 7 条
[1]   Lead insertion by supraclavicular approach of the subclavian vein puncture [J].
Antonelli, D ;
Freedberg, NA ;
Rosenfeld, T .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (03) :379-380
[2]   USE OF THE CONTRALATERAL SUBCLAVIAN VEIN FOR PLACEMENT OF ATRIAL ELECTRODES IN CHRONICALLY VVI-PACED PATIENTS [J].
BELOTT, PH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (04) :781-783
[3]  
Bongiorni Maria Grazia, 2005, Ital Heart J, V6, P261
[4]   Clinical study of the laser sheath for lead extraction: The total experience in the United States [J].
Byrd, CL ;
Wilkoff, BL ;
Love, CJ ;
Sellers, TD ;
Reiser, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (05) :804-808
[5]   Resynchronization therapy for the treatment of heart failure [J].
Saxon, LA ;
Ellenbogen, KA .
CIRCULATION, 2003, 108 (09) :1044-1048
[6]   Prevalence of central venous occlusion in patients with chronic defibrillator leads [J].
Sticherling, C ;
Chough, SP ;
Baker, RL ;
Wasmer, K ;
Oral, H ;
Tada, H ;
Horwood, L ;
Kim, MH ;
Pelosi, F ;
Michaud, GF ;
Strickberger, SA ;
Morady, F ;
Knight, BP .
AMERICAN HEART JOURNAL, 2001, 141 (05) :813-816
[7]   Pacemaker upgrade for recurrent pacemaker syndrome using a redundant contralateral electrode in a patient with bilateral venous stenoses [J].
Sulke, N ;
Tan, K ;
Bostock, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (03) :378-379