Biodegradable and metallic interference screws in anterior cruciate ligament reconstruction surgery using hamstring tendon grafts -: Prospective randomized study of radiographic results and clinical outcome

被引:66
作者
Laxdal, Gauti [1 ]
Kartus, Jueri
Eriksson, Bengt I.
Faxen, Eva
Sernert, Ninni
Karlsson, Jon
机构
[1] Sahlgrenska Univ Hosp Ostra, Dept Orthopaed, SE-41685 Gothenburg, Sweden
[2] NU Sjukvarden, Trollhattan, Sweden
[3] Fyrbodal Res Inst, Uddevalla, Sweden
关键词
anterior cruciate ligament reconstruction; biodegradable interference screws; metallic interference screws; hamstring tendon graft;
D O I
10.1177/0363546506288014
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The use of biodegradable screws in anterior cruciate ligament reconstruction has grown in popularity. Purpose: To compare the clinical and radiographic results in arthroscopically assisted anterior cruciate ligament reconstruction using 4-strand hamstring tendon grafts and either metallic (metal group) or biodegradable (PLLA group) interference screw fixation. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A randomized series of 77 patients, all with a unilateral anterior cruciate ligament rupture, was included in the study. The preoperative assessments in both groups were similar in gender, Tegner activity level, Lysholm score, KT-1000 arthrometer measurements, and single-legged hop test results. In both groups, interference screw fixation of the graft was used at both ends, and 68 of 77 (88%) patients returned for a radiographic examination at 6 and 24 months, respectively. Results: At follow-up, no significant differences were found between the 2 groups in KT-1 000 arthrometer laxity measurements, Tegner activity level, or Lysholm score. The PLLA group had a significantly better outcome in the single-begged hop test and the final International Knee Documentation Committee classification (P =.007 and P =.03, respectively). At 6 and 24 months after the index operation, the PLLA group displayed significantly larger drill holes on the radiographs than did the metal group on both the tibial (8.1 vs 6.6 mm at 6 months [P =.0007]; 6.0 vs 3.2 mm at 24 months [P <.0001]) and femoral sides (7.8 vs 5.6 mm at 6 months [P <.0001]; 6.3 vs 1.9 mm at 24 months [P <.0001]). Conclusion: There were significantly larger radiographically visible drill holes on both the tibial and femoral sides in the PLLA group compared with the metal group at 6 and 24 months. Clinical examination at 2 years revealed no major differences between the groups. The larger drill holes in the PLLA group did not correlate with inferior clinical results.
引用
收藏
页码:1574 / 1580
页数:7
相关论文
共 51 条
[1]
Anterior cruciate ligament reconstruction: Bone-patellar tendon-bone compared with double semitendinosus and gracilis tendon grafts - A prospective, randomized clinical trial [J].
Aglietti, P ;
Giron, F ;
Buzzi, R ;
Biddau, F ;
Sasso, F .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (10) :2143-2155
[2]
PATELLAR TENDON VERSUS DOUBLED SEMITENDINOSUS AND GRACILIS TENDONS FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
AGLIETTI, P ;
BUZZI, R ;
ZACCHEROTTI, G ;
DEBIASE, P .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (02) :211-218
[3]
BACH BR, 1989, AM J KNEE SURG, V2, P76
[4]
BACH BR, 1996, COURSE 401 ANTERIOR
[5]
Barber FA, 2000, BIOMATERIALS, V21, P2623
[6]
Anterior cruciate ligament replacement: Comparison of bone-patellar tendon-bone grafts with two-strand hamstring grafts - A prospective, randomized study [J].
Beynnon, BD ;
Johnson, RJ ;
Fleming, BC ;
Kannus, P ;
Kaplan, M ;
Samani, J ;
Renstrom, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (09) :1503-1513
[7]
Is a knee brace advantageous after anterior cruciate ligament surgery?: A prospective, randomised study with a two-year follow-up [J].
Brandsson, S ;
Faxén, E ;
Kartus, J ;
Eriksson, BI ;
Karlsson, J .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2001, 11 (02) :110-114
[8]
A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: extracortical versus anatomical fixation [J].
Buelow, JU ;
Siebold, R ;
Ellermann, A .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (02) :80-85
[9]
ARTHROSCOPICALLY ASSISTED RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT WITH USE OF AUTOGENOUS PATELLAR-LIGAMENT GRAFTS - RESULTS AFTER 24 TO 42 MONTHS [J].
BUSS, DD ;
WARREN, RF ;
WICKIEWICZ, TL ;
GALINAT, BJ ;
PANARIELLO, R .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1346-1355
[10]
Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation [J].
Charlton, WPH ;
Randolph, DA ;
Lemos, S ;
Shields, CL .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (04) :518-521