Independent versus sequential reading in ROC studies of computer-assist modalities: Analysis of components of variance

被引:33
作者
Beiden, SV
Wagner, RF
Doi, K
Nishikawa, RM
Freedman, M
Ben Lo, SC
Xu, XW
机构
[1] US FDA, Ctr Devices & Radiol Hlth, Rockville, MD 20857 USA
[2] Univ Chicago, Dept Radiol, Kurt Rossman Labs, Chicago, IL 60637 USA
[3] Georgetown Univ, ISIS Ctr, Washington, DC USA
[4] Deus Technol, Rockville, MD USA
关键词
computers; diagnostic aid; diagnostic radiology; observer performance; receiver operating characteristic curve (ROC);
D O I
10.1016/S1076-6332(03)80479-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Rationale and Objectives. The authors analyzed two methods for arranging the temporal sequencing of unaided versus computer-assisted reading in multiple-reader, multiple-case receiver operating characteristic studies of detection of solitary pulmonary nodules on chest radiographs. In the "independent" mode the readings are separated by about 1 month; in the "sequential" mode, the computer-assisted reading immediately follows the unassisted reading. Materials and Methods. The authors used the method of Beiden, Wagner, and Campbell (BWC) to decompose the components of variance of receiver operating characteristic accuracy measures into those that are correlated and those that are uncorrelated across reading conditions. Only the latter contribute to uncertainty in estimates of the difference in accuracy measures across reading conditions (unaided vs aided). This method was used to analyze data from two independent studies of the detection of solitary pulmonary nodules on chest radiographs. Results. In the sequential reading mode the components that were Correlated across reading conditions increased compared to the independent reading mode, as might be expected. What was not anticipated was the fact that the total reader variance was approximately the same for the two reading modes. The results were remarkably similar across the two independent studies analyzed. Conclusion. The sequential reading mode may thus be the more sensitive probe of the difference between unassisted and computer-assisted reading, if the mean effect is unperturbed (as here). It is also the least demanding on the logistics and investment of reader time. (C) AUR, 2002.
引用
收藏
页码:1036 / 1043
页数:8
相关论文
共 19 条
[1]
[Anonymous], HDB MED IMAGING
[2]
Components-of-variance models and multiple-bootstrap experiments: An alternative method for random-effects, receiver operating characteristic analysis [J].
Beiden, SV ;
Wagner, RF ;
Campbell, G .
ACADEMIC RADIOLOGY, 2000, 7 (05) :341-349
[3]
Components-of-variance models for random-effects ROC analysis: The case of unequal variance structures across modalities [J].
Beiden, SV ;
Wagner, RF ;
Campbell, G ;
Metz, CE ;
Jiang, YL .
ACADEMIC RADIOLOGY, 2001, 8 (07) :605-615
[4]
Analysis of uncertainties in estimates of components of variance in multivariate ROC analysis [J].
Beiden, SV ;
Wagner, RF ;
Campbell, G ;
Chan, HP .
ACADEMIC RADIOLOGY, 2001, 8 (07) :616-622
[5]
RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[6]
FREEDMAN M, 2001, MED IM PERC C 9 WARR
[7]
A receiver operating: Characteristic partial area index for highly sensitive diagnostic tests [J].
Jiang, YL ;
Metz, CE ;
Nishikawa, RM .
RADIOLOGY, 1996, 201 (03) :745-750
[8]
Effect of a computer-aided diagnosis scheme on radiologists' performance in detection of lung nodules on radiographs [J].
Kobayashi, T ;
Xu, XW ;
MacMahon, H ;
Metz, CE ;
Doi, K .
RADIOLOGY, 1996, 199 (03) :843-848
[9]
Computer-aided diagnosis of pulmonary nodules: Results of a large-scale observer test [J].
MacMahon, H ;
Engelmann, R ;
Behlen, FM ;
Hoffmann, KR ;
Ishida, T ;
Roe, C ;
Metz, CE ;
Doi, K .
RADIOLOGY, 1999, 213 (03) :723-726
[10]
MACMAHON H, 1996, RADIOLOGY, V201, P486