Improved quantitation for PET/CT image reconstruction with system modeling and anatomical priors

被引:48
作者
Alessio, Adam M. [1 ]
Kinahan, Paul E. [1 ]
机构
[1] Univ Washington, Med Ctr, Dept Radiol, Old Fisheries Ctr 200, Seattle, WA 98195 USA
关键词
PET/CT; anatomical priors; system modeling; PET reconstruction; detector response;
D O I
10.1118/1.2358198
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Accurate quantitation of positron emission tomography (PET) tracer uptake levels in tumors is important for staging and monitoring response to treatment. Quantitative accuracy in PET is particularly poor for small tumors because of system partial volume errors and smoothing operations. This work proposes a reconstruction algorithm to reduce the quantitative errors due to limited system resolution and due to necessary image noise reduction. We propose a method for finding and using the detection system response in the projection matrix of a statistical reconstruction algorithm. In addition, we use aligned anatomical information, available in PET/CT scanners, to govern the penalty term applied during each image update. These improvements are combined with Fourier rebinning in a clinically feasible algorithm for reconstructing fully three-dimensional PET data. Results from simulation and measured studies show improved quantitation of tumor values in terms of bias and variance across multiple tumor sizes and activity levels with the proposed method. At common clinical image noise levels for the detection task, the proposed method reduces the error in maximum tumor values by 11% compared to filtered back-projection and 5% compared to conventional iterative methods. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:4095 / 4103
页数:9
相关论文
共 35 条
[1]  
Alessio A., 2006, NUCL MED, V1
[2]   Modeling and incorporation of system response functions in 3-D whole body PET [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Lewellen, Thomas K. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) :828-837
[3]   Implementation of Monte Carlo coincident aperture functions in image generation of a high-resolution animal positron tomograph [J].
Böning, G ;
Pichler, BJ ;
Rafecas, M ;
Lorenz, E ;
Schwaiger, M ;
Ziegler, SI .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) :805-810
[4]   A unified approach to statistical tomography using coordinate descent optimization [J].
Bouman, CA ;
Sauer, K .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :480-492
[5]   Bayesian reconstruction and use of anatomical a Priori information for emission tomography [J].
Bowsher, JE ;
Johnson, VE ;
Turkington, TG ;
Jaszczak, RJ ;
Floyd, CE ;
Coleman, RE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (05) :673-686
[6]   Impact of FDG-PET on radiation therapy volume delineation in non-small-cell lung cancer [J].
Bradley, J ;
Thorstad, WL ;
Mutic, S ;
Miller, TR ;
Dehdashti, F ;
Siegel, BA ;
Bosch, W ;
Bertrand, RJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (01) :78-86
[7]   Patient-specific models for lung nodule detection and surveillance in CT images [J].
Brown, MS ;
McNitt-Gray, MF ;
Goldin, JG ;
Suh, RD ;
Sayre, JW ;
Aberle, DR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) :1242-1250
[8]   Minimal surfaces: a geometric three dimensional segmentation approach [J].
Caselles, V ;
Kimmel, R ;
Sapiro, G ;
Sbert, C .
NUMERISCHE MATHEMATIK, 1997, 77 (04) :423-451
[9]  
CHENG PM, 2004, RADIOLOGICAL SOC N A
[10]   Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels [J].
Comtat, C ;
Kinahan, PE ;
Fessler, JA ;
Beyer, T ;
Townsend, DW ;
Defrise, M ;
Michel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (01) :1-20