First clinical experience with the DeBakey VAD continuous-axial-flow pump for bridge to transplantation

被引:126
作者
Wieselthaler, GM
Schima, H
Hiesmayr, M
Pacher, R
Laufer, G
Noon, GP
DeBakey, M
Wolner, E
机构
[1] Univ Vienna, Dept Cardiothorac Surg, A-1090 Vienna, Austria
[2] Univ Vienna, Dept Cardiothorac Anesthesia & Intens Care, A-1090 Vienna, Austria
[3] Univ Vienna, Dept Cardiol, A-1090 Vienna, Austria
[4] Methodist Hosp, Baylor Coll Med, Dept Surg, Houston, TX 77030 USA
关键词
heart failure; heart-assist device; DeBakey VAD;
D O I
10.1161/01.CIR.101.4.356
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-A shortage of donor organs and increased numbers of deaths of patients on the waiting list for cardiac transplantation make mechanical circulatory support for a bridge to transplantation a standard clinical procedure. Continuous-flow rotary blood pumps offer exciting new perspectives. Methods and Results-Two male patients (ages 44 and 65 years) suffering from end-stage left heart failure were implanted with a DeBakey VAD axial-flow pump for use as a bridge to transplant. In the initial postoperative period, the mean pump now was 3.9+/-0.5 L/min, which equals a mean cardiac index (Cl) of 2.3+/-0.2 L.min(-1).m(-2). In both patients, the early postoperative phase was characterized by a completely nonpulsatile flow profile. However, with the recovery of heart function 8 to 12 days after implantation, increasing pulse pressures became evident, and net flow rose to 4.5+/-0.6 L/min, causing an increase of mean Cl up to 2.7+/-0.2 L.min(-1).m(-1). Patients were mobilized and put through regular physical training. Hemolysis stayed in the physiological range and increased only slightly fi om 2.1+/-0.8 mg/dL before surgery to 3.3+/-1.8 mg/dL 6 weeks after implantation. Conclusions-The first clinical implants of the DeBakey VAD axial-flow pump have demonstrated the device to be a promising measure of bridge-to-transplant mechanical support.
引用
收藏
页码:356 / 359
页数:4
相关论文
共 9 条
  • [1] Development of the Nimbus/Pittsburgh axial flow left ventricular assist system
    Butler, K
    Thomas, D
    Antaki, J
    Borovetz, H
    Griffith, B
    Kameneva, M
    Kormos, R
    Litwak, P
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 602 - 610
  • [2] DEBAKEY ME, 1998, HEART REPLACEMENT AR, V6, P407
  • [3] GOLDING LR, 1980, T AM SOC ART INT ORG, V26, P251
  • [4] A CLINICAL MONITORING-SYSTEM FOR CENTRIFUGAL BLOOD PUMPS
    HOLZER, S
    SCHERER, R
    SCHMIDT, C
    SCHWENDENWEIN, I
    WIESELTHALER, G
    NOISSER, R
    SCHIMA, H
    [J]. ARTIFICIAL ORGANS, 1995, 19 (07) : 708 - 712
  • [5] JOHNSTON GG, 1976, ARCH SURG-CHICAGO, V111, P1225
  • [6] Development of an implantable ventricular assist system
    Macris, MP
    Parnis, SM
    Frazier, OH
    Fuqua, JM
    Jarvik, RK
    [J]. ANNALS OF THORACIC SURGERY, 1997, 63 (02) : 367 - 370
  • [7] SCHIMA H, 1992, ARTIF ORGANS, V16, P195
  • [8] YADA I, 1983, T AM SOC ART INT ORG, V29, P520
  • [9] YAMAZAKI K, 1995, T AM SOC ART INT ORG, V41, P327