A natural compound (Reuterin) produced by Lactobacillus reuteri for hemoglobin polymerization as a blood substitute

被引:4
作者
Chen, YC
Chang, WH
Chang, Y
Huang, CM
Sung, HW [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem Engn, Hsinchu, Taiwan
[2] Natl Yang Ming Univ, Coll Med, Taipei 112, Taiwan
[3] Taichung Vet Gen Hosp, Div Cardiovasc Surg, Taichung, Taiwan
关键词
reuterin; hemoglobin; blood substitute; exchange transfusion;
D O I
10.1002/bit.20078
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Stroma-free hemoglobin (Hb) has been modified by pyridoxylation and followed by polymerization with glutaraldehyde as a blood substitute. Nevertheless, the reaction rate of pyridoxylated Hb (PLP-Hb) with glutaraldehyde is too fast to control its molecular weight distribution. Additionally, it was reported that glutaraldehyde is cytotoxic even at low doses. To overcome these problems, another aldehyde, beta-hydroxypropionaldehyde (beta-HPA), was used in the study to polymerize hemoglobin (PLP-Hb). beta-HPA is a natural compound (reuterin) produced by Lactobacillus reuteri. It was found that the maximum degree of PLP-Hb polymerization by reuterin (RR-PLP-Hb) was approximately 40% if the formation of high molecular (>500 kDa) polymers should be prevented. In contrast, at the same reaction condition, the glutaraldehyde-polymerized PLP-Hb solution became gel-like, due to overpolymerization. This indicated that the rate of PLP-Hb polymerization by reuterin was significantly slower than that by glutaraldehyde. With increasing the reaction temperature, PLP-Hb concentration, or reuterin-to-PLP-Hb molar ratio, the time to reach the maximum degree of PLP-Hb polymerization by reuterin became significantly shorter. Removal of unpolymerized PLP-Hb from the RR-PLP-Hb solution can be effectively achieved by a gel-filtration column. The P(50) value of the unmodified Hb solution was 14 torr, while that of the RR-PLP-Hb solution was 20 torr, an indication of lower oxygen affinity. Additionally, the oxygen-Hb dissociation curves for both test solutions had a sigmodial shape and a nearly 100% saturation at 100 torr. In the in vivo study, it was found that the animals treated with the RR-PLP-Hb solution all survived and remained healthy more than 3 months. In contrast, only one out of six rats survived for the control group treated with the unmodified Hb solution. Furthermore, it was found that the RR-PLP-Hb solution resulted in a significantly longer circulation time (approximate to 12 h) than the unmodified Hb solution (approximate to 1.5 h). These results suggest that the reuterin-polymerized PLP-Hb solution may be a new option in the development of blood substitutes. (C) 2004 Wiley Periodicals, Inc.
引用
收藏
页码:34 / 42
页数:9
相关论文
共 37 条
[1]  
Axelsson L., 1989, MICROB ECOL HEALTH D, V2, P131, DOI [DOI 10.3109/08910608909140210, 10.3109/08910608909140210]
[2]   AFFINITY LABELING OF POLYPHOSPHATE BINDING-SITE OF HEMOGLOBIN [J].
BENESCH, RE ;
BENESCH, R ;
RENTHAL, RD ;
MAEDA, N .
BIOCHEMISTRY, 1972, 11 (19) :3576-&
[3]  
BLEEKER WK, 1989, J LAB CLIN MED, V113, P151
[4]   RENAL HANDLING OF HEMOGLOBIN .I. GLOMERULAR FILTRATION [J].
BUNN, HF ;
ESHAM, WT ;
BULL, RW .
JOURNAL OF EXPERIMENTAL MEDICINE, 1969, 129 (05) :909-&
[5]   Feasibility study using a natural compound (reuterin) produced by Lactobacillus reuteri in sterilizing and crosslinking biological tissues [J].
Chen, CN ;
Sung, HW ;
Liang, HF ;
Chang, WH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 61 (03) :360-369
[6]  
Chung T.C., 1989, MICROB ECOL HEALTH D, V2, P137, DOI [10.3109/08910608909140211, DOI 10.3109/08910608909140211]
[7]  
DEVENUTO F, 1979, SURG GYNECOL OBSTET, V149, P417
[8]   PREPARATION AND EVALUATION OF PYRIDOXALATED POLYMERIZED HUMAN-HEMOGLOBIN [J].
DEVENUTO, F ;
ZEGNA, A .
JOURNAL OF SURGICAL RESEARCH, 1983, 34 (03) :205-212
[9]  
DEVENUTO F, 1977, TRANSFUSION, V17, P555
[10]  
Dobrogosz W.J., 1988, U.S. Patent, Patent No. [PCT/US88/01423, 8801423]