Extraction of the two-dimensional cardiothoracic ratio from digital PA chest radiographs: Correlation with cardiac function and the traditional cardiothoracic ratio

被引:24
作者
Browne, RFJ
O'Reilly, G
McInerney, D
机构
[1] Adelaide & Meath Hosp, Dept Radiol, Dublin 24, Tallaght, Ireland
[2] Adelaide & Meath Hosp, Dept Med Phys, Dublin 24, Tallaght, Ireland
关键词
cardiothoracic ratio; chest; digital radiography; computed radiography;
D O I
10.1007/s10278-003-1900-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to extract the two-dimensional (2D) cardiothoracic ratio from digital chest radiographs using image analysis software on a Magic View 300 system. We also wanted to investigate its correlation with cardiac function, as defined by left ventricular ejection fraction from MUGA scanning, and with the traditional one-dimensional cardiothoracic ratio. One hundred patients undergoing radionuclide ventriculography and concurrent digital PA chest radiography using a commercial selenium detector system were studied. The 2D cardiothoracic ratio was extracted by defining a region of interest around the cardiac and thoracic areas and calculating a ratio of the two pixel counts obtained. The one-dimensional cardiothoracic ratio was calculated in the traditional manner. Regression analysis was used to study the association between these ratios and the ejection fraction. The 2D ratio could be achieved on all radiographs after image manipulation. The traditional linear cardiothoracic ratio showed an inverse correlation with left ventricular ejection fraction (r= -0.45). The 2D cardiothoracic ratio showed an improved correlation (r = -0.52). Assuming that a left ventricular ejection fraction of 55% or more indicates normal cardiac function, the normal 2D cardiothoracic ratio is 0.23 or less and a ratio of 1:4 is suggested. The ratio of cardiac and thoracic area correlates better with cardiac function as assessed by left ventricular ejection fraction than the traditional linear cardiothoracic ratio. Two-dimensional cardiothoracic ratio is easily extracted and improves the data yield from digital PA chest radiographs on PACS systems.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 18 条
[1]   CORRELATION BETWEEN CHEST FILM AND ANGIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR SIZE [J].
CHIKOS, PM ;
FIGLEY, MM ;
FISHER, L .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 128 (03) :367-373
[2]  
CHIKOS PM, 1997, AM J ROENTGENOL, V128, P375
[3]   The cardiothoracic ratio - An index of cardiac enlargement [J].
Danzer, CS .
AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 1919, 157 :513-521
[4]   SOME PITFALLS IN EVALUATION OF CARDIAC CHAMBER ENLARGEMENT ON CHEST ROENTGENOGRAMS [J].
DINSMORE, RE ;
GOODMAN, DJ ;
SANDERS, CA .
RADIOLOGY, 1966, 87 (02) :267-&
[5]   ASSESSMENT OF CARDIAC-FUNCTION BY 3-DIMENSIONAL ECHOCARDIOGRAPHY COMPARED WITH CONVENTIONAL NONINVASIVE METHODS [J].
GOPAL, AS ;
SHEN, ZQ ;
SAPIN, PM ;
KELLER, AM ;
SCHNELLBAECHER, MJ ;
LEIBOWITZ, DW ;
AKINBOBOYE, OO ;
RODNEY, RA ;
BLOOD, DK ;
KING, DL .
CIRCULATION, 1995, 92 (04) :842-853
[6]  
Hada Y, 1995, J Cardiol, V26, P51
[7]   RELATIONSHIP OF CARDIOTHORACIC RATIO AND PLAIN FILM HEART VOLUME TO LATE SURVIVAL [J].
HAMMERMEISTER, KE ;
CHIKOS, PM ;
FISHER, L ;
DODGE, HT .
CIRCULATION, 1979, 59 (01) :89-95
[8]   RADIONUCLIDE MEASUREMENT OF LEFT-VENTRICULAR VOLUME - COMPARISON OF GEOMETRIC AND COUNTS-BASED METHODS [J].
MASSIE, BM ;
KRAMER, BL ;
GERTZ, EW ;
HENDERSON, SG .
CIRCULATION, 1982, 65 (04) :725-730
[9]   HEART MEASUREMENT - A SIMPLIFIED METHOD [J].
MEYER, RR .
RADIOLOGY, 1949, 52 (05) :691-700
[10]   THE RELIABILITY OF THE ROUTINE CHEST ROENTGENOGRAM FOR DETERMINATION OF HEART SIZE BASED ON SPECIFIC VENTRICULAR CHAMBER EVALUATION AT POSTMORTEM [J].
MURPHY, ML ;
BLUE, LR ;
THENABADU, PN ;
PHILLIPS, JR ;
FERRIS, EJ .
INVESTIGATIVE RADIOLOGY, 1985, 20 (01) :21-25