Cadmium(II)-selective membrane electrode based on a synthesized tetrol compound

被引:97
作者
Javanbakht, M
Shabani-Kia, A
Darvich, MR
Ganjali, MR
Shamsipur, M [1 ]
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
[2] Univ Tehran, Dept Chem, Tehran, Iran
关键词
cadmium ion-selective electrode; PVC membrane; 1,1 '-bicyclohexy]-1,1 '-2,2 '-tetrol; potentiometry;
D O I
10.1016/S0003-2670(99)00771-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new PVC membrane electrode for Cd2+ ions based on [1,1'-bicyclohexyl]-1,1',2,2'-tetrol as membrane carrier was prepared. The electrode exhibits a Nernstian response for Cd2+ over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 27.8 mV decade(-1). The limit of detection is 9.0 x 10(-6) M (1.0 mu g ml(-1)). The electrode has a response time of <15 s and a useful working pH range of 4.0-7.0. The proposed membrane sensor shows excellent discriminating ability towards Cd2+ ion with regard to several alkali, alkaline earth, transition and heavy metal ions. It was successfully applied for the direct determination of Cd2+ in solution and, as an indicator electrode, in potentiometric titrations of cadmium ion. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 54 条
[1]  
AMINI MK, 1991, INORG CHIM ACTA, V183, P65
[2]   PREPARATION OF NEUTRAL IONOPHORES FOR ALKALI AND ALKALINE-EARTH METAL CATIONS AND THEIR APPLICATION IN ION-SELECTIVE MEMBRANE ELECTRODES [J].
AMMANN, D ;
BISSIG, R ;
GUGGI, M ;
PRETSCH, E ;
SIMON, W ;
BOROWITZ, IJ ;
WEISS, L .
HELVETICA CHIMICA ACTA, 1975, 58 (06) :1535-1548
[3]  
AMMANN D, 1983, ION SEL ELECTRODE R, V5, P3
[4]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[5]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[6]   STUDY OF CALCIUM-ION SELECTIVE ELECTRODES CONTAINING SIMON IONOPHORES USING IMPEDANCE METHODS - BULK PROPERTIES [J].
ARMSTRONG, RD ;
TODD, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1988, 257 (1-2) :161-166
[7]   RECENT ADVANCES IN THE DEVELOPMENT AND ANALYTICAL APPLICATIONS OF BIOSENSING PROBES [J].
ARNOLD, MA ;
MEYERHOFF, ME .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1988, 20 (03) :149-196
[8]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[9]   SUITABLE ION-SELECTIVE SENSORS FOR LEAD AND CADMIUM ANALYSIS [J].
BORRACCINO, A ;
CAMPANELLA, L ;
SAMMARTINO, MP ;
TOMASSETTI, M ;
BATTILOTTI, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :535-539
[10]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687