Hand-held dynamometry reliability in persons with neuropathic weakness

被引:46
作者
Kilmer, DD [1 ]
McCrory, MA [1 ]
Wright, NC [1 ]
Rosko, RA [1 ]
Kim, HR [1 ]
Aitkens, SG [1 ]
机构
[1] UNIV CALIF DAVIS,DEPT NUTR,SACRAMENTO,CA 95817
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1997年 / 78卷 / 12期
关键词
D O I
10.1016/S0003-9993(97)90311-7
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To determine test-retest reliability of hand-held dynamometry (HHD) in measuring strength of persons with neuropathic weakness. Design: Intratester and intertester reliability of HHD-measured strength over a 7- to 10-day period. In addition, HHD knee strength was compared with criterion standard of fixed dynamometry (FD). Setting: Human performance laboratory of a university. Participants: Convenience sample of ambulatory outpatients with Hereditary Motor and Sensory Neuropathy, Type I (HMSN) (n = 10) and able-bodied controls (CTL) (n = 11). Main Outcome Measure: Maximal isometric torque. Results: Intratester intraclass correlation coefficients (ICCs) were high, generally ranging from .82 to .96 for HHD- and FD-measured strength for both HMSN and CTL groups. There were no significant differences between sesions for HHD-measured strength, while ED-measured strength was only significantly different for knee extension (p < .01). Intertester reliability was generally good for both HHD- and FD-measured strength, with ICCs ranging from .72 to .97 for HMSN and CTL groups. Exceptions were knee extensors and ankle dorsiflexors for the CTL group. Knee extensor strength was significantly lower measured by HHD compared with FD (p < .01), but knee flexor strength was similar for the two methods. Conclusion: HHD appears to be a reliable method to measure maximal isometric strength in persons with neurogenic weakness, and may be useful to quickly and objectively evaluate strength in the clinical setting. (C) 1997 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:1364 / 1368
页数:5
相关论文
共 18 条
[1]  
AGRE JC, 1987, ARCH PHYS MED REHAB, V68, P454
[2]  
AITKENS SG, 1993, ARCH PHYS MED REHAB, V74, P1168
[3]   QUANTITATIVE MOTOR-ASSESSMENT IN AMYOTROPHIC-LATERAL-SCLEROSIS [J].
ANDRES, PL ;
HEDLUND, W ;
FINISON, L ;
CONLON, T ;
FELMUS, M ;
MUNSAT, TL .
NEUROLOGY, 1986, 36 (07) :937-941
[4]  
[Anonymous], 1989, Applied Linear Regression Models
[5]   HAND-HELD COMPARED WITH ISOKINETIC DYNAMOMETRY FOR MEASUREMENT OF STATIC KNEE EXTENSION TORQUE (PARALLEL RELIABILITY OF DYNAMOMETERS) [J].
BOHANNON, RW .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1990, 11 (03) :217-222
[6]   COMPARISON OF A HAND-HELD AND FIXED DYNAMOMETER IN MEASURING STRENGTH OF PATIENTS WITH NEUROMUSCULAR DISEASE [J].
BRINKMANN, JR .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1994, 19 (02) :100-104
[7]  
BYL N N, 1988, Journal of Orthopaedic and Sports Physical Therapy, V9, P399
[8]   PROFILES OF NEUROMUSCULAR DISEASES HEREDITARY MOTOR AND SENSORY NEUROPATHY, TYPE-I AND TYPE-II [J].
CARTER, GT ;
ABRESCH, RT ;
FOWLER, WM ;
JOHNSON, ER ;
KILMER, DD ;
MCDONALD, CM .
AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1995, 74 (05) :S140-S149
[9]  
de Boer A, 1982, Eng Med, V11, P169, DOI 10.1243/EMED_JOUR_1982_011_047_02
[10]  
Dyck PJ, 1994, PERIPHERAL NEUROPATH, P1094