Sequential injection spectrophotometric analysis of nitrite in natural waters using an on-line solid-phase extraction and preconcentration method

被引:47
作者
Miró, M [1 ]
Cladera, A [1 ]
Estela, JM [1 ]
Cerdà, V [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma de Mallorca 07071, Spain
关键词
D O I
10.1039/a910263i
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automatic sequential injection analysis (SIA) set-up for the isolation, preconcentration and spectrophotometric determination of nitrite in waters based on the Shinn reaction was designed and evaluated. The system performs the on-line azo dye formation and its subsequent extraction on a solid phase (monofunctional C-18), which is held inside a glass column incorporated into the system. A large sample volume (maximum, 10 ml) is sequentially segmented with sulfanilamide and N-(1-naphthyl)ethylenediamine dihydrochloride by using an iterative method. The azo dye collected is eluted with a small volume of 80% methanol and conducted to a diode-array spectrophotometer for quantitative analysis. It has been proved that the retention efficiency is maintained for up to 45 sample injections of 10 ml in spite of the high chromogenic reagent acidity. Nitrite has been determined within the 13.4-160 ng ml(-1) and 0.83-20 ng ml (-1) ranges for 1 and 10 ml of sample, respectively. For these volumes, the detection limits are 5.9 and 0.32 ng ml (-1), the enhancement factors 17 and 170 and the sample throughput 15 and 3 h(-1), respectively. A maximum RSD of 4.0% was achieved in all determinations. It is an advantage of this approach that it is possible to use the same mass calibration graph for any sample volume.
引用
收藏
页码:943 / 948
页数:6
相关论文
共 42 条
[1]  
[Anonymous], STAND METH EX WAT WA
[2]  
Becerra E, 1999, LAB ROBOTICS AUTOMAT, V11, P131, DOI 10.1002/(SICI)1098-2728(1999)11:3<131::AID-LRA2>3.0.CO
[3]  
2-9
[4]   CONFIGURATION WITH INTERNALLY COUPLED VALVES TO OVERCOME SHORTCOMINGS IN THE SIMULTANEOUS DETERMINATION OF NITRITE AND NITRATE BY FLOW-INJECTION ANALYSIS [J].
BERMUDEZ, B ;
RIOS, A ;
DECASTRO, MDL ;
VALCARCEL, M .
TALANTA, 1988, 35 (10) :810-812
[5]   Sequential injection sandwich technique for the simultaneous determination of nitrate and nitrite [J].
Cerdà, A ;
Oms, MT ;
Forteza, R ;
Cerdà, V .
ANALYTICA CHIMICA ACTA, 1998, 371 (01) :63-71
[6]  
CERDA A, 1998, THESIS U BALEARIC IS
[7]   FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF NITRITE [J].
CHAURASIA, A ;
VERMA, KK .
TALANTA, 1994, 41 (08) :1275-1279
[8]   AQUEOUS NITRITE ION DETERMINATION BY SELECTIVE REDUCTION AND GAS-PHASE NITRIC-OXIDE CHEMILUMINESCENCE [J].
DUNHAM, AJ ;
BARKLEY, RM ;
SIEVERS, RE .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :220-224
[9]   REACTION DETECTOR WITH 3-DIMENSIONAL COILED OPEN TUBES IN HPLC [J].
ENGELHARDT, H ;
NEUE, UD .
CHROMATOGRAPHIA, 1982, 15 (07) :403-408
[10]  
FANG Z, 1993, FLOW INJECTION SEPAR, P88