Simultaneous immunoassay using piezoelectric immunosensor array and robust method

被引:16
作者
Chu, X
Jiang, JH
Shen, GL
Yu, RQ
机构
[1] HUNAN UNIV,INST CHEMOMETR & CHEM SENSING TECHNOL,CHANGSHA 410082,PEOPLES R CHINA
[2] HUNAN UNIV,DEPT CHEM & CHEM ENGN,CHANGSHA 410082,PEOPLES R CHINA
关键词
immunoassay; piezoelectric quartz crystal array; robust regression; LTS; PLS;
D O I
10.1016/S0003-2670(96)00308-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simultaneous immunoassay technique has been developed for the determination of dual analytes, immunoglobulin M (IgM) and C-reactive protein (CRP) by constructing a piezoelectric quartz crystal array system. This array system was composed of five piezoelectric quartz crystals. Each crystal was immobilized with an antibody mixture, which had a fixed ratio of anti-IgM to anti-CRP antibodies but worked under different detection conditions, i.e., in five buffer media with different pH values. The specificity of immunoreactions and the effect of pH on the sensitivity of the immunosensors were investigated. Applications of this array system in the estimation of the concentration of unknown samples using three linear regression methods, i.e., ordinary least squares (OLS), partial least squares (PLS) and least terminated squares (LTS), were presented. Results of these samples showed that the LTS estimator is a promising tool for multi-analyte piezoelectric immunoassay.
引用
收藏
页码:185 / 193
页数:9
相关论文
共 27 条
  • [1] *BEIJ MED COLL, 1980, EXPT IMMUNOLOGY, P53
  • [2] BLAKE C, 1982, CLIN CHEM, V28, P1469
  • [3] SENSOR ARRAY FOR CARBOHYDRATES AND AMINO-ACIDS BASED ON ELECTROCATALYTIC MODIFIED ELECTRODES
    CHEN, Q
    WANG, J
    RAYSON, G
    TIAN, BM
    LIN, YH
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (03) : 251 - 254
  • [4] Piezoelectric immunosensor for the detection of immunoglobulin M
    Chu, X
    Lin, ZH
    Shen, GL
    Yu, RQ
    [J]. ANALYST, 1995, 120 (12) : 2829 - 2832
  • [5] GOW SM, 1986, CLIN CHEM, V32, P2191
  • [6] A NOVEL COLORED LATEX TEST FOR THE DETECTION AND IDENTIFICATION OF MORE THAN ONE ANTIGEN
    HADFIELD, SG
    LANE, A
    MCILLMURRAY, MB
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 1987, 97 (02) : 153 - 158
  • [7] HAGE DS, 1991, ANAL CHEM, V63, pR206
  • [8] SIMULTANEOUS IMMUNOASSAY USING ELECTROCHEMICAL DETECTION OF METAL-ION LABELS
    HAYES, FJ
    HALSALL, HB
    HEINEMAN, WR
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (11) : 1860 - 1865
  • [9] HEMMILA I, 1987, CLIN CHEM, V33, P2281
  • [10] Hoskuldsson A., 1988, J CHEMOMETR, V2, P211, DOI DOI 10.1002/CEM.1180020306