Calibration of a laser galvanometric scanning system by adapting a camera model

被引:21
作者
Cui, Suochao [1 ]
Zhu, Xiao [1 ]
Wang, Wei [1 ]
Xie, Yunhui [1 ]
机构
[1] Huazhong Univ Sci & Technol, Inst Optoelect Sci & Engn, Wuhan 430074, Peoples R China
关键词
DISTORTION;
D O I
10.1364/AO.48.002632
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We propose a new calibration method for a laser galvanometric scanning (LGS) system by adapting the camera model to model the LGS system. The similarity between the camera system and the LGS system has been investigated and exploited. The distortion parameters are acquired by solving a nonlinear least squares problem of 12 coefficients using the Levenberg-Marquardt algorithm. The efficiency of the calibration is improved. Experiments are conducted to verify the proposed model. (c) 2009 Optical Society of America
引用
收藏
页码:2632 / 2637
页数:6
相关论文
共 9 条
[1]  
Chen Xiaoming, 2006, Journal of Xi'an Jiaotong University, V40, P587
[2]  
Faugeras O., 1993, 3 DIMENSIONAL COMPUT
[3]   Accurate procedure for the calibration of a structured light system [J].
Legarda-Sáenz, R ;
Bothe, T ;
Jüptner, WP .
OPTICAL ENGINEERING, 2004, 43 (02) :464-471
[4]  
More J. J., 1978, Proceedings of the Biennial Conference on numerical analysis, P105
[5]  
WEISZ JR, 1991, P SOC PHOTO-OPT INS, V1454, P265
[6]   CAMERA CALIBRATION WITH DISTORTION MODELS AND ACCURACY EVALUATION [J].
WENG, JY ;
COHEN, P ;
HERNIOU, M .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (10) :965-980
[7]  
WU T, 1987, ACTA OPT SINICA, V7, P261
[8]   Correction of the image distortion for laser galvanometric scanning system [J].
Xie, J ;
Huang, SH ;
Duan, ZC ;
Shi, YS ;
Wen, SF .
OPTICS AND LASER TECHNOLOGY, 2005, 37 (04) :305-311
[9]   A flexible new technique for camera calibration [J].
Zhang, ZY .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2000, 22 (11) :1330-1334