The measurement and meaning of void volumes in reversed-phase liquid chromatography

被引:172
作者
Rimmer, CA [1 ]
Simmons, CR [1 ]
Dorsey, JG [1 ]
机构
[1] Florida State Univ, Dept Chem & Biochem, Tallahassee, FL 32306 USA
关键词
void volume; reviews;
D O I
10.1016/S0021-9673(02)00730-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The seemingly simple process of measuring the mobile phase volume, V, in reversed-phase liquid chromatography has eluded unambiguous agreement for over 25 years. Examples exist in the literature where the reported volume is physically impossible, either equal to or larger than the empty column volume, or being so small that it would represent a total porosity of half the theoretical limit for well-packed columns. Here we review the many proposals for methods of measurement, and compare and critique them. At this time, there is still no consensus for the best method of measurement, and workers are urged to critically examine values they measure, to insure they are at least physically possible. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:219 / 232
页数:14
相关论文
共 74 条
[1]   COLUMN DEAD VOLUME IN LIQUID-CHROMATOGRAPHY [J].
ALHEDAI, A ;
MARTIRE, DE ;
SCOTT, RPW .
ANALYST, 1989, 114 (08) :869-875
[2]   EVALUATION OF DEAD SPACE IN CHROMATOGRAPHIC SYSTEMS [J].
ALTHAMIR, WK ;
PURNELL, JH ;
WELLINGTON, CA ;
LAUB, RJ .
JOURNAL OF CHROMATOGRAPHY, 1979, 173 (02) :388-391
[3]   ON THE DETERMINATION OF THE HOLD-UP TIME IN REVERSED PHASE LIQUID-CHROMATOGRAPHY [J].
BERENDSEN, GE ;
SCHOENMAKERS, PJ ;
GALAN, LD ;
VIGH, G ;
VARGAPUCHONY, Z .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (11) :1669-1686
[4]   SOME PRACTICAL CONSIDERATIONS WHEN DETERMINING THE VOID VOLUME IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BIDLINGMEYER, BA ;
WARREN, FV ;
WESTON, A ;
NUGENT, C ;
FROEHLICH, PM .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (07) :275-279
[5]   MEASUREMENT OF DEUTERIUM-OXIDE ELUTION DATA IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY WITH MICROWAVE INDUCED PLASMA DETECTION [J].
BILLIET, HAH ;
VANDALEN, JPJ ;
SCHOENMAKERS, PJ ;
DEGALAN, L .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :847-851
[6]  
Chankvetadze B, 2001, J SEP SCI, V24, P635, DOI 10.1002/1615-9314(20010801)24:8<635::AID-JSSC635>3.0.CO
[7]  
2-Q
[8]   THE IMPORTANCE OF DEAD VOLUME IN THE OPTIMIZATION OF SEPARATIONS IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY USING TERNARY SOLVENTS [J].
COLIN, H ;
KRSTULOVIC, A ;
GUIOCHON, G ;
BOUNINE, JP .
CHROMATOGRAPHIA, 1983, 17 (04) :209-214
[9]   THE CASE OF THE ELUSIVE TM VALUES IN HPLC [J].
DAIGNAULT, LG ;
JACKMAN, DC ;
RILLEMA, DP .
CHROMATOGRAPHIA, 1989, 27 (3-4) :156-158
[10]   SELECTIVE RETENTION OF CATECHOLAMINES AND THEIR DERIVATIVES IN REVERSED-PHASE ION-PAIR PARTITION CHROMATOGRAPHY [J].
DEJONG, J ;
VANVALKENBURG, CFM ;
TJADEN, UR .
JOURNAL OF CHROMATOGRAPHY, 1985, 322 (01) :43-53