A finite element model for performing intravascular ultrasound elastography of human atherosclerotic coronary arteries

被引:55
作者
Baldewsing, RA
De Korte, CL
Schaar, JA
Mastik, F
Van Der Steen, AFW
机构
[1] Erasmus Univ, Med Ctr, Ctr Thorax, NL-3000 DR Rotterdam, Netherlands
[2] Interuniv Cardiol Inst Netherlands, Utrecht, Netherlands
[3] Univ Childrens Hosp, Clin Phys Lab, Nijmegen, Netherlands
关键词
intravascular ultrasound elastography; strain imaging; human coronary arteries; vulnerable plaque; finite element method; Young's modulus; phantom;
D O I
10.1016/j.ultrasmedbio.2004.04.005
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Intravascular ultrasound (US) elastography measures in an artery the arterial radial strain and displays it in an elastogram. An elastogram adds diagnostic information, such as the proneness of a plaque to rupture and its material composition. However, radial strain depends upon the material properties of an artery, including geometry and used catheter position. Therefore, there is not always a one-to-one correspondence between radial strain and rupture-proneness or material composition. Both the dependence and the correspondence can be quantified after a proper finite element model (FEM) is available. Therefore, this paper proposes a FEM and shows that it can model the arterial strain behavior. Its modelling capability was evaluated by comparing simulated with measured elastograms. Measured elastograms were processed from radiofrequency (RF) data obtained in vitro from six objects: a vessel-mimicking phantom and five excised human atherosclerotic coronary arteries. it FEM was created for each object and used to simulate an elastogram; the material properties and geometry of the FEM were obtained from the histology of the object. Comparison was performed upon high strain regions (HStR), because these regions have proven to contain plaques that show the hallmarks of vulnerable plaques. Eight HStR were automatically identified from the five arteries. Statistical tests showed that there was no significant difference between simulated and corresponding measured elastograms in location, surface area or mean strain value of a HStR. The results demonstrate that the FEM can simulate elastograms measured from arteries. As such, the FEM may help in quantifying strain-dependencies and assist in tissue characterization by reconstructing a Young's modulus image from a measured elastogram. (E-mail: r.baldewsing@erasniusmc.nl) (C) 2004 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:803 / 813
页数:11
相关论文
共 49 条
[1]  
AANACKOVIC TM, 2000, THEORY ELASTICITY SC
[2]  
Baldewsing RA, 2003, ULTRASON, P1879
[3]   Finite element modeling and intravascular ultrasound elastography of vulnerable plaques: parameter variation [J].
Baldewsing, RA ;
de Korte, CL ;
Schaar, JA ;
Mastik, F ;
van der Steen, AFW .
ULTRASONICS, 2004, 42 (1-9) :723-729
[4]  
BALDEWSING RA, 2002, P 2002 IEEE ULTR INT, P1873
[5]  
BALDEWSING RA, 2003, P 2 INT C ULTR MEAS, P75
[6]   Axial strain imaging of intravascular data: Results on polyvinyl alcohol cryogel phantoms and carotid artery [J].
Brusseau, E ;
Fromageau, J ;
Finet, G ;
Delachartre, P ;
Vray, D .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (12) :1631-1642
[7]   COMPRESSIBILITY OF ARTERIAL WALL [J].
CAREW, TE ;
VAISHNAV, RN ;
PATEL, DJ .
CIRCULATION RESEARCH, 1968, 23 (01) :61-&
[8]  
Cespedes EI, 1996, ULTRASON, P1181, DOI 10.1109/ULTSYM.1996.584201
[9]   DISTRIBUTION OF CIRCUMFERENTIAL STRESS IN RUPTURED AND STABLE ATHEROSCLEROTIC LESIONS - A STRUCTURAL-ANALYSIS WITH HISTOPATHOLOGICAL CORRELATION [J].
CHENG, GC ;
LOREE, HM ;
KAMM, RD ;
FISHBEIN, MC ;
LEE, RT .
CIRCULATION, 1993, 87 (04) :1179-1187
[10]   Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity [J].
Chu, KC ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) :314-319