Computer-assisted transfer of programmed elutions in reversed-phase high-performance liquid chromatography

被引:17
作者
Garcia-Lavandeira, J. [1 ]
Martinez-Pontevedra, J. A. [1 ]
Lores, M. [1 ]
Cela, R. [1 ]
机构
[1] Univ Santiago de Compostela, Inst Invest & Anal Alimentario, Dipartimento Quim Analit Nutr & Bromatol, E-15782 Santiago De Compostela, Spain
关键词
computer-assisted method development; transfer gradients; RPLC;
D O I
10.1016/j.chroma.2006.06.025
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Computer-assisted procedures were used to simulate modifications in chromatograms caused by the transfer of elution programmes between instruments with significantly different dwell volumes. Moreover, for the first time the same approach was used to modify the elution programmes to match the chromatograms produced in the different instruments. The process may consist of making minor modifications to gradient programmes or transforming the original gradient programme into a stepwise gradient profile and/or the simultaneous programming of flow and solvent composition. The combination of these approaches has been shown to have an enormous potential for producing matched chromatograms in instrumental systems with dwell volumes that differ by several millilitres. The efficiency and robustness of the proposed procedure is demonstrated with a variety of compounds (two different mixtures of 10 and 11 analytes), mobile phases (methanol and acetonitrile gradients), flow rates (0.5-1.5 mL/min range), temperatures (35-45 degrees C interval) and gradient profiles (linear, multilinear, curved and stepwise). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:17 / 26
页数:10
相关论文
共 26 条
[1]  
*ADV CHEM DEV INC, 2004, ACD LC SIM V 8 0 TUT
[2]  
[Anonymous], 1990, COMPUTER ASSISTED ME
[3]  
[Anonymous], 1989, GENETIC ALGORITHM SE
[4]  
BEINERT WD, 2001, LC GC EUR, V14, P34
[5]   THE PREOPT PACKAGE FOR PRE-OPTIMIZATION OF GRADIENT ELUTIONS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CELA, R ;
BARROSO, CG ;
VISERAS, C ;
PEREZBUSTAMANTE, JA .
ANALYTICA CHIMICA ACTA, 1986, 191 :283-297
[6]  
Cela R, 1999, QUIM ANAL, V18, P29
[7]   PREOPT-W: A simulation program for off-line optimization of binary gradient separations in HPLC .1. Fundamentals and overview [J].
Cela, R ;
Lores, M .
COMPUTERS & CHEMISTRY, 1996, 20 (02) :175-191
[8]  
Dolan JW, 2000, LC GC N AM, V18, P1228
[9]  
Dolan JW, 2003, LC GC EUR, V16, P252
[10]   Maintaining fixed band spacing when changing column dimensions in gradient elution [J].
Dolan, JW ;
Snyder, LR .
JOURNAL OF CHROMATOGRAPHY A, 1998, 799 (1-2) :21-34